RX2520 M1
Upgrade and Maintenance Manual
65
Basic hardware procedures
Connecting power cords to the mains
V
CAUTION!
The power supply automatically adjusts to any mains voltage in the
range of 100 VAC to 240 VAC. You may only operate the server if its
rated voltage range corresponds to the local mains voltage.
Figure 12: Securing power cord
Ê
Connect the power connector (1) to the power supply unit.
Ê
Close the cable clamp around the power cord (2) and lock the cable
clamp (3) to secure the power cord.
Ê
Connect the mains plug to a grounded mains outlet in the in-house power
supply network or a power outlet of the rack socket strip (see also
"PRIMECENTER Rack System" assembly guide).
I
To provide true phase redundancy, the second power supply should
be connected to a different AC power source from the other supply. If
one AC power source should fail, the server will still continue to run.
I
It takes about 60 seconds until power-on becomes possible.
Содержание PRIMERGY RX2520 M1
Страница 36: ...36 Upgrade and Maintenance Manual RX2520 M1 Before you start ...
Страница 120: ...120 Upgrade and Maintenance Manual RX2520 M1 Power supply units ...
Страница 162: ...162 Upgrade and Maintenance Manual RX2520 M1 Hard disk drives solid state drives ...
Страница 169: ...RX2520 M1 Upgrade and Maintenance Manual 169 System fan Figure 73 Removing the fan box Ê Remove the two screws ...
Страница 220: ...220 Upgrade and Maintenance Manual RX2520 M1 Expansion cards and backup units ...
Страница 230: ...230 Upgrade and Maintenance Manual RX2520 M1 Main memory ...
Страница 283: ...RX2520 M1 Upgrade and Maintenance Manual 283 Accessible drives Ê Enabling BitLocker functionality on page 93 ...
Страница 310: ...310 Upgrade and Maintenance Manual RX2520 M1 Accessible drives ...
Страница 410: ...410 Upgrade and Maintenance Manual RX2520 M1 Cables ...