System board and components
14.4.2 Removing the TPM
V
CAUTION!
Advise your contact persons that they must provide you with TPM
backup copies. For security reasons, the TPM must be restored/re-
saved by the customer. After installing a new system board, the TPM
must be enabled. You may not clear the TPM data.
If the contact persons
DO NOT
have a backup copy available, inform
them that replacing the TPM will cause to lose all data.
Field Replaceable Unit
(FRU)
Hardware: 30 minutes
Tools:
Removing the system board:
– Phillips PH2 / (+) No. 2 screw driver
Removing the TPM:
– flat nose pliers
– thin slotted screw driver (2 x 0.4 mm)
(
*
(
*
)
For the Japanese market:
– Dedicated TPM screw driver (CWZ8291A)