QuadroM 32x/8L/26x/12Li/26xi Manual II: Administrator's Guide
Administrator’s Menus
QuadroM 32x/8L/26x/12Li/26xi; (SW Version 5.2.x)
40
•
Extension
– this account refers to all extensions created on the Quadro. The password for default extensions is not factory reset safe
but is contained in the backed up configuration. Permissions for an extension to access each GUI page can be adjusted here.
The
User Rights Management
page consists of two pages.
The
Users
page is used to manage the available users on the
Quadro. The
Roles
page is used to assign the corresponding
permissions to the users.
The
Users
page contains a table where the Administrator and
Local Administrator users are listed. This page allows them to
modify the passwords of available users in the table and to
manage the Local Administrator’s account. The following
functional buttons are available on this page:
The
Change Password
functional button is used to change
the password of the Administrator and Local Administrator
user’s account. Select one of the available users in the table
by toggling the corresponding checkbox and press
Change
Password
to open the corresponding page.
Fig. II-70: Users page at User Rights Management
The
Change Password
page is used to change the user’s password.
The
GUI Access Password
offers the following components:
The
Old Password
text field is only present when
modifying the Administrator account password and requires
the current password of the Administrator. An error
message prevents entering the wrong password.
The
New Password
text field requires a new password for
the Administrator or Local Administrator. Reentering the
new password in the
Confirm New Password
text field will
confirm the new password.
Fig. II-71: Change Password page
Please Note:
The password can consist of numeric values and symbols. Up to twenty (0-20) digits and symbols are allowed.
The
Phone Access Password
offers the following components:
The
Old Password
text field is present when modifying the Administrator account password and requires the current password of the Administrator.
An error message prevents entering the wrong password.
The
New Password
text field requires a new password for the Administrator. Reentering the new password in the
Confirm New Password
text field
will confirm the new password. The password can consist of numeric values only. Up to twenty (0-20) digits are allowed. A corresponding warning
appears if any other symbols are inserted.
The
Enable User
and
Disabled User
functional buttons are used to enable or disable the Local Administrator’s account.
Attention:
It is highly recommended to define a proper and non-empty password on this page if the extension is being used for the Call Relay
service from the Quadro's Auto Attendant.
Please Note:
The Administrator’s account cannot be disabled.
The
Roles
page contains a table where the Local
Administrator and Extensions users are listed. This page
allows you to set the permissions to the GUI pages for each
user in the table.
The
Edit
functional button leads to the
Change Access
Rights
page where a list of user specific GUI pages is
displayed. Select the user in the table and press
Edit
to
manage the permission for the corresponding user.
Fig. II-72: Roles page at User Rights Management