Accessories
Micropilot NMR84
98
Hauser
14.2 Communication-specific accessories
WirelessHART adapter SWA70
• Is used for the wireless connection of field devices
• The WirelessHART adapter can be easily integrated into field devices and existing
infrastructures, offers data protection and transmission safety and can be operated in
parallel with other wireless networks
For details, see Operating Instructions BA00061S
Gauge Emulator, Modbus to BPM
• Using the protocol converter, it is possible to integrate a field device into a host system
even if the field device does not know the communication protocol of the host system.
Eliminates vendor lock-in for field devices.
• Field communication protocol (field device): Modbus RS485
• Host communication protocol (host system): Enraf BPM
• 1 measuring device per Gauge Emulator
• Separate power supply: 100 to 240 V
AC
, 50 to 60 Hz, 0.375 A, 15 W
• Several approvals for the hazardous area
Gauge Emulator, Modbus to TRL/2
• Using the protocol converter, it is possible to integrate a field device into a host system
even if the field device does not know the communication protocol of the host system.
Eliminates vendor lock-in for field devices.
• Field communication protocol (field device): Modbus RS485
• Host communication protocol (host system): Saab TRL/2
• 1 measuring device per Gauge Emulator
• Separate power supply: 100 to 240 V
AC
, 50 to 60 Hz, 0.375 A, 15 W
• Several approvals for the hazardous area
14.3 Service-specific accessories
Commubox FXA195 HART
For intrinsically safe HART communication with FieldCare via the USB interface
For details, see "Technical Information" TI00404F
Commubox FXA291
Connects Hauser field devices with a CDI interface (= Hauser Common
Data Interface) and the USB port of a computer or laptop
Order number: 51516983
For details, see "Technical Information" TI00405C
DeviceCare SFE100
Configuration tool for HART, PROFIBUS and FOUNDATION Fieldbus field devices
DeviceCare is available for download at
www.software-products.endress.com
. You need to
register in the Hauser software portal to download the application.
Technical Information TI01134S
FieldCare SFE500
FDT-based plant asset management tool
It can configure all smart field units in your system and helps you manage them. By using
the status information, it is also a simple but effective way of checking their status and
condition.
Technical Information TI00028S
Содержание Micropilot NMR84
Страница 177: ...Micropilot NMR84 Operating menu Endress Hauser 177 Additional information Read access Operator Write access Maintenance ...
Страница 204: ...Operating menu Micropilot NMR84 204 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 219: ...Micropilot NMR84 Operating menu Endress Hauser 219 Additional information Read access Operator Write access Maintenance ...
Страница 238: ...Operating menu Micropilot NMR84 238 Endress Hauser Read access Operator Write access Maintenance ...
Страница 255: ......
Страница 256: ...www addresses endress com 71545626 71545626 ...