Operating menu
Micropilot NMR84
218
Hauser
"Safety settings" submenu
Navigation
Setup → Advanced setup → Safety settings
Output echo lost
Navigation
Setup → Advanced setup → Safety settings → Output echo lost
Description
Defines the output behavior in case of a lost echo.
Additional information
Read access
Operator
Write access
Service
Meaning of the options
•
Last valid value
The last value before the occurence of the echo is kept.
•
Alarm
The device generates an alarm.
Delay time echo lost
Navigation
Setup → Advanced setup → Safety settings → Delay echo lost
Description
Time between the echo loss and the reaction defined for the output.
User entry
0 to 99
999.9 s
Factory setting
60.0 s
Additional information
Read access
Operator
Write access
Maintenance
Safety distance
Navigation
Setup → Advanced setup → Safety settings → Safety distance
Description
Defines the safety distance (measured from the reference point). A warning is issued if the
level rises into the safety distance.
User entry
Signed floating-point number
Factory setting
0 mm
Содержание Micropilot NMR84
Страница 177: ...Micropilot NMR84 Operating menu Endress Hauser 177 Additional information Read access Operator Write access Maintenance ...
Страница 204: ...Operating menu Micropilot NMR84 204 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 219: ...Micropilot NMR84 Operating menu Endress Hauser 219 Additional information Read access Operator Write access Maintenance ...
Страница 238: ...Operating menu Micropilot NMR84 238 Endress Hauser Read access Operator Write access Maintenance ...
Страница 255: ......
Страница 256: ...www addresses endress com 71545626 71545626 ...