Micropilot NMR84
Operating menu
Hauser
179
Liquid temperature
Navigation
Setup → Advanced setup → Application → Tank config → Temperature → Liquid
temp.
Description
Shows the average or spot temperature of the measured liquid.
Additional information
Read access
Operator
Write access
-
Air temperature source
Navigation
Setup → Advanced setup → Application → Tank config → Temperature → Air temp.
source
Description
Defines source from which the air temperature is obtained.
Selection
• Manual value
• HART device 1 ... 15 temperature
• AIO B1-3 value
• AIO C1-3 value
• AIP B4-8 value
• AIP C4-8 value
Factory setting
Manual value
Additional information
Read access
Operator
Write access
Maintenance
Manual air temperature
Navigation
Setup → Advanced setup → Application → Tank config → Temperature → Manual air
temp.
Prerequisite
Air temperature source (→ 179)
Manual value
Description
Defines the manual value of the air temperature.
User entry
–50 to 300 °C
Factory setting
25 °C
Additional information
Read access
Operator
Write access
Maintenance
Содержание Micropilot NMR84
Страница 177: ...Micropilot NMR84 Operating menu Endress Hauser 177 Additional information Read access Operator Write access Maintenance ...
Страница 204: ...Operating menu Micropilot NMR84 204 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 219: ...Micropilot NMR84 Operating menu Endress Hauser 219 Additional information Read access Operator Write access Maintenance ...
Страница 238: ...Operating menu Micropilot NMR84 238 Endress Hauser Read access Operator Write access Maintenance ...
Страница 255: ......
Страница 256: ...www addresses endress com 71545626 71545626 ...