Operating menu
Micropilot NMR84
176
Hauser
• AIO B1-3 value
• AIO C1-3 value
• AIP B4-8 value
• AIP C4-8 value
Factory setting
Manual value
Additional information
Read access
Operator
Write access
Maintenance
Manual water level
Navigation
Setup → Advanced setup → Application → Tank config → Level → Man. water level
Prerequisite
Manual value
Description
Defines the manual value of the bottom water level.
User entry
–2
000 to 5
000 mm
Factory setting
0 mm
Additional information
Read access
Operator
Write access
Maintenance
Water level
Navigation
Setup → Advanced setup → Application → Tank config → Level → Water level
Description
Shows the bottom water level.
Additional information
Read access
Operator
Write access
-
Blocking distance
Navigation
Setup → Advanced setup → Application → Tank config → Level → Blocking dist.
Description
No echos are evaluated within the blocking distance BD. Therefore, BD can be used to
suppress interference echos in the vicinity of the antenna.
User entry
Positive floating-point number
Factory setting
800 mm
Содержание Micropilot NMR84
Страница 177: ...Micropilot NMR84 Operating menu Endress Hauser 177 Additional information Read access Operator Write access Maintenance ...
Страница 204: ...Operating menu Micropilot NMR84 204 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 219: ...Micropilot NMR84 Operating menu Endress Hauser 219 Additional information Read access Operator Write access Maintenance ...
Страница 238: ...Operating menu Micropilot NMR84 238 Endress Hauser Read access Operator Write access Maintenance ...
Страница 255: ......
Страница 256: ...www addresses endress com 71545626 71545626 ...