Micropilot NMR84
Diagnostics and troubleshooting
Hauser
91
Diagnostic
number
Short text
Remedy instructions
Status
signal
[from the
factory]
Diagnostic
behavior
[from the
factory]
560
Calibration mandatory
1. Carry out weight calibration
2. Carry out reference
calibration
3. Carry out drum calibration
C
Alarm
564
DIO B1-2 source no longer
valid
Change input source
C
Warning
565
DIO B3-4 source not valid
Change input source
C
Warning
566
DIO C1-2 source no longer
valid
Change input source
C
Warning
567
DIO C3-4 source no longer
valid
Change input source
C
Warning
568
DIO D1-2 source no longer
valid
Change input source
C
Warning
569
DIO D3-4 source no longer
valid
Change input source
C
Warning
585
Simulation distance
Deactivate simulation
C
Warning
586
Record map
Recording of mapping
please wait
C
Warning
598
DIO A1-2 source no longer
valid
Change input source
C
Warning
599
DIO A3-4 source no longer
valid
Change input source
C
Warning
Diagnostic of process
801
Energy too low
Increase supply voltage
S
Warning
803
Current loop
1. Check device configuration.
2. Check wiring.
F
Alarm
803
Current loop 1 to 2
M
Warning
803
Current loop
C
Warning
825
System temperature
1. Check ambient temperature
2. Check process temperature
S
Warning
825
System temperature
F
Alarm
826
Sensor temperature
1. Check ambient temperature
2. Check process temperature
S
Warning
826
Sensor temperature
F
Alarm
844
Process value out of
specification
1. Check process value
2. Check application
3. Check sensor
S
Warning
844
Process value out of
specification
S
Warning
903
Current loop 1 to 2
1. Check device configuration.
2. Check wiring.
F
Alarm
904
Digital output 1 to 8
1. Check device configuration.
2. Check wiring.
F
Alarm
941
Echo lost
1. Check process value
2. Check application
3. Check sensor
S
Warning
942
In safety distance
1. Check level
2. Check safety distance
3. Reset self holding
S
Warning
943
In blocking distance
Reduced accuracy
Check level
S
Warning
950
Advanced diagnostics
Maintain your diagnostic event
M
Warning
Содержание Micropilot NMR84
Страница 177: ...Micropilot NMR84 Operating menu Endress Hauser 177 Additional information Read access Operator Write access Maintenance ...
Страница 204: ...Operating menu Micropilot NMR84 204 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 219: ...Micropilot NMR84 Operating menu Endress Hauser 219 Additional information Read access Operator Write access Maintenance ...
Страница 238: ...Operating menu Micropilot NMR84 238 Endress Hauser Read access Operator Write access Maintenance ...
Страница 255: ......
Страница 256: ...www addresses endress com 71545626 71545626 ...