Operating menu
Micropilot NMR84
202
Hauser
User entry
0 to 3
000 kg/m³
Factory setting
800 kg/m³
Additional information
Read access
Maintenance
Write access
Maintenance
Density value
Navigation
Setup → Advanced setup → Application → Tank calculation → HTMS → Density value
Description
Shows the calculated product density.
Additional information
Read access
Operator
Write access
-
Minimum level
Navigation
Setup → Advanced setup → Application → Tank calculation → HTMS → Min. level
Description
Defines the minimum product level for a HTMS calculation.
If Lp - V falls below the limit defined in this parameter, the density retains its last value or
the manual value is used instead.
User entry
0 to 20
000 mm
Factory setting
7
000 mm
Additional information
Read access
Operator
Write access
Maintenance
Minimum pressure
Navigation
Setup → Advanced setup → Application → Tank calculation → HTMS → Min.
pressure
Description
Defines the minimum pressure for a HTMS calculation.
If the pressure P1 (or the difference P1 - P3) falls below the limit defined in this
parameter, the density retains its last value or the manual value is used instead.
User entry
0 to 100 bar
Factory setting
0.1 bar
Содержание Micropilot NMR84
Страница 177: ...Micropilot NMR84 Operating menu Endress Hauser 177 Additional information Read access Operator Write access Maintenance ...
Страница 204: ...Operating menu Micropilot NMR84 204 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 219: ...Micropilot NMR84 Operating menu Endress Hauser 219 Additional information Read access Operator Write access Maintenance ...
Страница 238: ...Operating menu Micropilot NMR84 238 Endress Hauser Read access Operator Write access Maintenance ...
Страница 255: ......
Страница 256: ...www addresses endress com 71545626 71545626 ...