Gammapilot M FMG60 PROFIBUS PA
Installation
Hauser
17
3.3
Water cooling
For the versions of the Gammapilot with water cooling jacket, the following applies:
• Material: 316L
• Water connection: 2 x G 1/4"A, DIN ISO 228
• Inlet temperature: max. 40 °C (104 °F)
• Outlet temperature: max. 50 °C (122 °F) (temperature monitoring recommended)
• Water pressure: 4 to 6 bar (60 to 90 psi)
A0018078
A
T <75 °C (167 °F)
B
T <120 °C (248 °F)
CAUTION
!
Detector or cooling jacket can be damaged if the cooling water freezes.
‣
Empty cooling jacket or protect against freezing.
WARNING
!
Pressurized water cooling system!
‣
Do not open the cylinder screws (see figure below) when pressurized.
A0023205
1
Cylinder screws
A
B
G
1
/4"A
G
1
/4"A
*
1
CAUTION
!
To consider when using the water cooling
jacket
‣
It is recommended to ground the water
cooling jacket separately at the provided
earth terminal (see picture above)
‣
The ambient temperature of the
compartment housing must not exceed
75 °C (167 °F). This is also valid, if water
cooling is applied.
‣
The three screws, connecting the pipe
housing to the compartment housing, must
not
be opened.
A0018068