Wiring
Gammapilot M FMG60 PROFIBUS PA
22
Hauser
Terminal(s)
Meaning
0
Grounding of the cable screen
1)
1)
Rated cross section > 1 mm
2
(17 AWG)
1, 2
Power supply
2)
2)
Rated cross section max. 2.5 mm
2
(14 AWG)
Compartment 2:
3, 4
Compartment 1:
(3)
1
,(4)
1
Signal output, depending on communication version:
• 4-20mA with HART
• PROFIBUS PA
• Foundation Fieldbus
(Depending on the device version ordered, the signal output is in connection compartment 1
or 2, see below)
NOTICE
For the versions of the Gammapilot M with fieldbus plug connectors (M12 or 7/8"), the
signal output is wired in compartment 2 on delivery and connected to the fieldbus plug
connector (see below, section "Fieldbus connectors"). In this case, the housing needs
not to be opened for connecting the signal line.
5, 6
Pulse input (for cascading mode; is used for master and slave)
7, 8
Pulse output (for cascading mode; is used for slave and end slave)
9, 10, 11, 12
PT-100 input (4-wire)
13
Plug for display and operating module VU331 (normally in FHX40);
is wired on delivery and connected to the FHX40 plug
14
Protective earth
)
15
Protective earth or grounding of the cable screen
)
The cables used at terminals 14 or 15 must at least have the same cross section as the
cables at terminals 1 and 2.
Содержание Gammapilot M FMG60
Страница 95: ...Gammapilot M FMG60 PROFIBUS PA Technical data Endress Hauser 95 ...
Страница 104: ...www addresses endress com 71298583 ...