Adjustments
94
Pos : 5. 18 /0025 Übersc hrift en/ELTRA 1.1 Übersc hrift en/11 I nduction g enerator c ontrol ELTRA @ 6\ mod_1369387490836_9. doc x @ 42096 @ 2 @ 1
4.9 Induction generator control
Pos : 5. 19 /0010 ELTR A/ 0015 s ervic e_ins truc tions/C S-2000_s er vice/ 10Adjust ment s_C S-2000/ 1050 M odul Induction g enerator contr ol @ 9\ mod_1425542716597_9. doc x @ 74670 @ @ 1
Fig. 74: HF 42
Fig. 75: Jumper settings HF 42
Current control:
The current control provides a safer and more accurate control of the furnace intensity.
–
Set the jumper J2 to B1-B2. .
–
Connect a digital multi meter on TP1 (TP15 is GND).
Adjust only, while the furnace is active:
–
Start the analysis, adjusting P2 until 6.3V DC is reached on TP1 (for copper analysis,
adjust 1.2V DC).
TP15 TP16 TP17 TP18 TP19
+24V -12V +5V
+12V +20V
GND
TP20
H F 4 2
1 2 0 1 6
P1
P 3
P 2
T P 1
T P 2
T P 1 0
T P 1 1
T P 1 3
T P 1 4
T P 8
T P 7
T P 9
T P 1 2
T P 6
T P 3
J 3
J 2
TP5
TP4
Содержание CS-2000
Страница 2: ...2 Copyright Copyright by Eltra GmbH Retsch Allee 1 5 D 42781 Haan Germany ...
Страница 6: ...Notes on service instructions 6 ...
Страница 72: ...Adjustments 72 Fig 57 Gas flow regulation The flow controller mainly consists of the following components ...
Страница 77: ...Adjustments 77 Fig 61 IRC 1 3 ...
Страница 107: ...Service 107 Fig 91 Tubes to squeeze ...
Страница 120: ...Miscellaneous 120 6 1 2 Left hand side Fig 106 Left hand side view ...
Страница 122: ...Miscellaneous 122 6 1 3 Right hand side Fig 107 Right hand side view ...
Страница 129: ...Miscellaneous 129 6 1 7 Infrared cell Fig 111 Infrared cell ...
Страница 139: ...Miscellaneous 139 Fig 119 Left hand side power wiring 6 2 3 Valve wiring ...
Страница 140: ...Miscellaneous 140 Fig 120 Valve wiring 6 2 4 Control signal wiring Fig 121 Control signal wiring ...
Страница 142: ...Miscellaneous 142 6 2 6 IR cell internal signals Fig 123 IR current supply new version ...
Страница 145: ...Miscellaneous 145 6 3 2 Gas flow for induction furnace when furnace is open ...
Страница 146: ...Miscellaneous 146 6 3 3 Gas flow for resistance furnace ...
Страница 147: ...Miscellaneous 147 6 3 4 Valve contolling ...
Страница 160: ...Copyright Copyright by Eltra GmbH Retsch Allee 1 5 D 42781 Haan Germany ...