EMR-5000
IM02602012E
Name
Description
Bkr.Isum Intr trip
Signal: Maximum permissible Summation of the interrupting (tripping) currents exceeded in at least one
phase.
Bkr.Res TripCmdCr
Signal: Resetting of the Counter: total number of trip commands
Bkr.Res Isum trip
Signal: Reset summation of the tripping currents
Bkr.WearLevel Alarm
Signal: Breaker Wear curve Alarm
Bkr.WearLevel Lockout
Signal: Breaker Wear Curve Lockout Level
Bkr.Res Bwear Curve
Signal: Reset of the Breaker Wear maintenance curve.
Bkr.Isum Intr ph Alm
Signal: Alarm, the per hour Sum (Limit) of interrupting currents has been exceeded.
Bkr.Res Isum Intr ph Alm
Signal: Reset of the Alarm, "the per hour Sum (Limit) of interrupting currents has been exceeded".
MStart.Active
Signal: Active
MStart.Blo TripCmd
Signal: Trip Command blocked
MStart.Trip
Signal: Trip
MStart.TripCmd
Signal: Trip Command
MStart.Start
Signal: Motor is in start mode
MStart.Run
Signal: Motor is in run mode
MStart.Stop
Signal: Motor is in stop mode
MStart.Blo
Signal: Motor is blocked for starting or transition to Run mode
MStart.NOCSBlocked
Signal: Motor is prohibited to start due to number of cold start limits
MStart.SPHBlocked
Signal: Motor is prohibited to start due to starts per hour limits
MStart.SPHBlockAlarm
Signal: Motor is prohibited to start due to starts per hour limits, would come active in the next stop
MStart.TBSBlocked
Signal: Motor is prohibited to start due to time between starts limits
MStart.ThermalBlock
Signal: Thermal block
MStart.RemBlockStart
Signal: Motor is prohibited to start due to external blocking through digital input DI
MStart.TransitionTrip
Signal: Start transition fail trip
MStart.ZSSTrip
Signal: Zero speed trip (possible locked rotor)
MStart.INSQSP2STFaill
Signal: Fail to transit from stop to start based on reported back time
MStart.INSQSt2RunFail
Signal: Fail to transit from start to run based on reported back time
MStart.LATBlock
Signal: Long acceleration timer enforced
MStart.ColdStartSeq
Signal: Motor cold start sequence flag
MStart.ForcedStart
Signal: Motor being forced to start
MStart.TripPhaseReverse
Signal: Relay tripped because of phase reverse detection
MStart.EmergOverrideDI
Signal: Emergency override start blocking through digital input DI
MStart.EmergOverrideUI
Signal: Emergency override start blocking through front panel
MStart.ABKActive
Signal: Anti-backspin is active. For certain applications, such as pumping a fluid up a pipe, the motor may be
driven backward for a period of time after it stops. The anti-backspin timer prevents starting the motor while it
is spinning in the reverse direction.
MStart.GOCStartBlock
Signal: Ground Instantaneous Overcurrent Start Delay. GOC (Instantaneous Overcurrent) elements are
blocked for the time programmed under this parameter
www.eaton.com
995
Содержание EMR-5000
Страница 62: ...EMR 5000 IM02602012E Ethernet RJ45 Terminal Marking www eaton com 62 1 8 TxD TxD RxD N C N C RxD N C N C...
Страница 271: ...EMR 5000 IM02602012E Fault Recorder Module Signals Signal Description Res record Signal Delete Record www eaton com 271...
Страница 524: ...EMR 5000 IM02602012E Motor Protection Curves Motor Protection Curve Example 1 www eaton com 524...
Страница 525: ...EMR 5000 IM02602012E Motor Protection Curve Example 2 without RTDs www eaton com 525...
Страница 526: ...EMR 5000 IM02602012E Motor Protection Curve Example 3 with RTDs www eaton com 526...
Страница 930: ...EMR 5000 IM02602012E Real Time Clock Running Reserve of the Real Time Clock 1 year min www eaton com 930...