Monitoring Precautions
Precautions During Care
WARNING !
Absorbent is caustic and is a strong irritant to
the eyes, skin, and respiratory tract. When
emptying absorber, take care not to spill its
contents.
WARNING !
Always follow accepted hospital procedures
for handling equipment contaminated with
body fluids.
WARNING !
Use only original Nellcor SpO
2
sensors.
Follow Instructions for Use of the sensors –
incorrect positioning or use can cause tissue
damage.
WARNING !
The operator is responsible for manual
selection of the anesthetic agent and for
correct filling of the anesthetic vaporizer!
WARNING !
Always set audible alarm volume to a level
that is sufficiently loud with respect to the
general noise level of the surroundings.
WARNING !
The alarm silence button is intended to provide
a way of muting audible alarms while corrective
action is taken. Failure to identify and correct
alarm situations may result in patient injury.
WARNING !
Warning or Caution level audible alarms
require immediate operator attention to avert
or to prevent development of situations with
the possibility of patient injury.
Precautions During Operation
WARNING !
Manual ventilation is not possible when Julian
is in standby mode!
WARNING !
Devices connected to the auxiliary outlets will
not be powered by the uninterruptible power
supply in the event of a power failure.
WARNING !
Do not perform leak test while a patient is
connected to the anesthesia workstation.
WARNING !
Absorbent is caustic and is a strong irritant to
the eyes, skin, and respiratory tract. When
emptying or filling absorber, take care not to
spill its contents.
WARNING !
Always follow accepted hospital procedures
for handling body fluids.
WARNING !
Always use an anesthesia system that has
been cleaned and disinfected and has been
successfully tested to be ready for operation.
WARNING !
Devices mounted on extended arms on the left
or right side of the machine can cause tip
over.
Summary of WARNINGS and CAUTIONS
Precautions During Preparation
Precautions During Operation
Monitoring Precautions
Precautions During Care
Operating Instructions Julian SW 3.n
14
CAUTION !
Do not use anesthetic gas scavenging sytem in
combination with extracorporal oxygenator.
Содержание Julian
Страница 1: ...Julian Anesthesia Workstation Operating Instructions Software 3 n XXXX ...
Страница 3: ...XXXXXXX ...
Страница 6: ...Operating Instructions Julian SW 3 n 6 This page intentionally left blank ...
Страница 16: ...Operating Instructions Julian SW 3 n 16 This page intentionally left blank ...
Страница 64: ...Operating Instructions Julian SW 3 n 64 This page intentionally left blank ...
Страница 121: ...Contents Troubleshooting 122 Troubleshooting Contents Operating Instructions Julian SW 3 n 121 Troubleshooting ...
Страница 136: ...Operating Instructions Julian SW 3 n 136 This page intentionally left blank ...
Страница 144: ...Technical Data APL Valve Characteristics 144 APL Valve Characteristics ...