VXLAN Hypervisor
•
Service Node (SN)
•
Legacy TOR
Network
Virtualization
Platform (NVP)
Controller
NVP Controller is the network controller for managing cloud components. The OVSDB protocol is the
protocol used for communication between VTEPs and the controller. In the current release, the qualified
controller for the VXLAN Gateway function is NSX-from VMWare. The top-level functions of NVP are:
•
Provide a GUI for creating service gateways.
•
Manage the VTEPs.:
– Binds Port and VLAN
– Install VTEP tunnels
•
Distribute the VTEPs to MAC binding to all relevant VTEPs.
•
Provide an interface for cloud orchestration in cloud data center management.
VTEP (VXLAN
Tunnel End Point)
VTEPs work as the open vSwitch running on the hypervisor on a virtualized server or as the VXLAN
Gateway or as the Service Node (SN) that is responsible for flooding. The VTEPs are responsible for
encapsulation and decapsulation of VXLAN headers.
VXLAN Gateways
VXLAN Gateways act as the VTEPs that encapsulate and decapsulate VXLAN headers. The roles and
responsibilities of the Gateway are:
•
Connects to the NVP client based on user configuration.
•
Advertises south-facing VXLAN capable ports to the NVP client.
•
Creates logical networks based on messages from the NVP.
•
Creates tunnels to VTEPs based on messages from the NVP.
•
Binds the Port and VLAN to logical networks based on messages from the NVP.
•
Binds MACs to the VTEP and logical network based on messages from the NVP.
•
Advertises MACs learnt on south-facing VXLAN capable-ports to the NVP client.
VXLAN Hypervisor
It is the VTEP that connects the Virtual Machines (VM) to the underlay legacy network to the physical
infrastructure.
Service Node(SN)
It is also another VTEP, but it is fully managed by NSX. The purpose of SN is to be the central replication
engine for flooded packets
Legacy TOR
It is a TOR switch, which performs routing or switching decisions.
Functional Overview of VXLAN Gateway
The following section is the functional overview of VXLAN Gateway:
1.
Provides connectivity between a Virtual server infrastructure and a Physical server infrastructure.
2.
Provides the functions performed by a VTEP in a virtual server infrastructure. The functions of a VTEP are:
•
VTEP is responsible for creating one or more logical networks.
•
VTEP is responsible for identifying and binding a Port and VLAN to a logical network
•
VTEP maintains MAC bindings to a VTEP.
•
VTEP is typically managed by a network orchestrator. When the device functions as VTEP, VXLAN from VMWare is the
network orchestrator.
950
Virtual Extensible LAN (VXLAN)
Содержание S4048-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Страница 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Страница 477: ...Figure 68 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 477 ...
Страница 480: ...Figure 70 Inspecting a LAG Port on BRAVO Using the show interface Command 480 Link Aggregation Control Protocol LACP ...
Страница 481: ...Figure 71 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 481 ...
Страница 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Страница 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Страница 524: ...Figure 89 Configuring PIM in Multiple Routing Domains 524 Multicast Source Discovery Protocol MSDP ...
Страница 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Страница 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Страница 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Страница 633: ...Policy based Routing PBR 633 ...
Страница 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Страница 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...