cd Change current directory
clear Reset functions
copy Copy from one file to another
delete Delete a file
dir List files on a filesystem
disable Turn off privileged commands
enable Turn on privileged commands
exit Exit from the EXEC
format Format a filesystem
fsck Filesystem check utility
pwd Display current working directory
rename Rename a file
reset Reset selected card
show Show running system information
ssh-peer-stack-unit Open a SSH connection to the peer stack-unit
start Start shell
telnet-peer-stack-unit Open a telnet connection to the peer stack-unit
terminal Set terminal line parameters
upload Upload file
Dell(standby)#
-----------------CONSOLE ACCESS ON A MEMBER----------------------------
Stack(stack-member-0)#?
reset-self Reset this unit alone
show Show running system information
You can connect two units with two or more stacking cables in case of a stacking port or cable failure. Removal of only one of the
cables does not trigger a reset.
Important Points to Remember
•
You can stack up to six systems.
•
You cannot stack one system with other system types.
•
You cannot enable stacking and virtual link trunking (VLT) simultaneously on the device. To convert a stacked unit to VLT, refer to
Reconfiguring Stacked Switches as VLT
.
•
•
All the ports in a stack-group are placed in stacking mode. Unused ports in that group cannot be used as data ports.
•
Stacking on the device is accomplished through front-end user ports on the chassis.
•
All stack units must have the same version of Dell Networking OS.
Stacking Installation Tasks
The following are the stacking installation tasks.
•
•
Add Units to an Existing Stack
•
Create an Stack
Stacking is enabled on the device using the front end ports.
No configuration is allowed on front end ports used for stacking. Stacking can be made between 10G ports of two units or 40G ports
of two units. The stack links between the two units are grouped into a single LAG.
826
Stacking
Содержание S4048-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Страница 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Страница 477: ...Figure 68 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 477 ...
Страница 480: ...Figure 70 Inspecting a LAG Port on BRAVO Using the show interface Command 480 Link Aggregation Control Protocol LACP ...
Страница 481: ...Figure 71 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 481 ...
Страница 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Страница 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Страница 524: ...Figure 89 Configuring PIM in Multiple Routing Domains 524 Multicast Source Discovery Protocol MSDP ...
Страница 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Страница 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Страница 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Страница 633: ...Policy based Routing PBR 633 ...
Страница 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Страница 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...