The following example shows the
diag
command (stack member).
[output from master unit]
Dell#diag stack-unit 2
Warning - the stack unit will be pulled out of the stack for diagnostic execution
Proceed with Diags [confirm yes/no]: yes
Warning - diagnostic execution will cause multiple link flaps on the peer side - advisable
to shut directly connected ports
Proceed with Diags [confirm yes/no]: yes
Dell#00:03:13: %S25P:2 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 2
00:03:13 : Approximate time to complete these Diags ... 6 Min
00:03:13 : Diagnostic test results will be stored on stack unit 2 file: flash:/
TestReport-SU-2.txt
Dell#00:03:35: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 2 down - card removed
00:08:50: %STKUNIT1-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 2 present
00:09:00: %STKUNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from Stack unit 2 (type S25P, 28 ports)
00:09:00: %S25P:2 %CHMGR-0-PS_UP: Power supply 0 in unit 2 is up
00:09:00: %STKUNIT1-M:CP %CHMGR-5-STACKUNITUP: Stack unit 2 is up
[output from the console of the unit in which diagnostics are performed]
Dell(stack-member-2)#
Diagnostic test results are stored on file: flash:/TestReport-SU-2.txt
Diags completed... Rebooting the system now!!!
The following example shows the
show file flash:\\
command (standalone member).
Dell#show file flash://TestReport-SU-0.txt
*******************************S-Series Diagnostics***********************
Board : S4810 Dell Inc.
Stack Unit Board Serial Number : HADL112220111
CPU Version : MPC8536E, Version: 1.1
CPLD REVISION : 0x7
CPLD BOARD TYPE : 0x1
Diag image based on build : 9-4(0-89)
Stack Unit Board temperature : 50 Degree C
Stack Unit Number : 1
**************************Stack Unit EEPROM INFO**************************
**************MFG INFO*******************
Data in Chassis Eeprom Mfg Info is listed as...
Vendor Id : 07
Country Code : 02
Date Code : 01222011
Serial Number : HADL112220111
Part Number : 7590009602
Product Revision : A
Product Order Number : S4810P-AC
**************************** S4810 LEVEL 0 DIAGNOSTICS**************************
diagS4810ChkPsuPresence[625]: ERROR: Psu : 0 is not present
Test 1.000 - Psu Power Good Test .................................... NOT PRESENT
Test 1.001 - Psu Power Good Test .................................... PASS
Test 1 - Psu Power Good Test ....................................... FAIL
diagS4810ChkPsuPresence[625]: ERROR: Psu : 0 is not present
Test 2.000 - Fan Psu Status test .................................... NOT PRESENT
Test 2.001 - Fan Psu Status test .................................... PASS
Test 2 - Fan Psu Status Test ....................................... FAIL
Test 3.000 - Fan board presence Test ................................ PASS
Test 3.001 - Fan board presence Test ................................ PASS
Test 3 - Fan Board Presence Test ................................... PASS
Test 4.000 - Board Fan Status Test .................................. PASS
Test 4.001 - Board Fan Status Test .................................. PASS
1004
Debugging and Diagnostics
Содержание S4048-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Страница 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Страница 477: ...Figure 68 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 477 ...
Страница 480: ...Figure 70 Inspecting a LAG Port on BRAVO Using the show interface Command 480 Link Aggregation Control Protocol LACP ...
Страница 481: ...Figure 71 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 481 ...
Страница 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Страница 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Страница 524: ...Figure 89 Configuring PIM in Multiple Routing Domains 524 Multicast Source Discovery Protocol MSDP ...
Страница 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Страница 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Страница 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Страница 633: ...Policy based Routing PBR 633 ...
Страница 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Страница 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...