Displaying Show sFlow on an Interface
To view sFlow information on a specific interface, use the following command.
•
Display sFlow configuration information and statistics on a specific interface.
EXEC mode
show sflow interface
interface-name
Examples of the sFlow
show
Commands
The following example shows the
show sflow interface
command.
Dell#show sflow interface tengigabitethernet 1/1
Te 1/1
sFlow type :Ingress
Configured sampling rate :16384
Actual sampling rate :16384
Counter polling interval :20
Extended max header size :128
Samples rcvd from h/w :0
The following example shows the
show running-config interface
command.
Dell#show running-config interface tengigabitethernet 1/16
!
interface TenGigabitEthernet 1/16
no ip address
mtu 9252
ip mtu 9234
switchport
sflow ingress-enable
sflow sample-rate 8192
no shutdown
Displaying Show sFlow on a Stack-unit
To view sFlow statistics on a specified Stack-unit, use the following command.
•
Display sFlow configuration information and statistics on the specified interface.
EXEC mode
show sflow stack—unit
slot-number
Example of Viewing sFlow Configuration (Line Card)
Dell#show sflow Stack-unit 1
Stack-unit 1
Samples rcvd from h/w :165
Samples dropped for sub-sampling :69
Total UDP packets exported :77
UDP packets exported via RPM :77
UDP packets dropped :
Configuring Specify Collectors
The
sflow collector
command allows identification of sFlow collectors to which sFlow datagrams are forwarded.
You can specify up to two sFlow collectors. If you specify two collectors, the samples are sent to both.
•
Identify sFlow collectors to which sFlow datagrams are forwarded.
CONFIGURATION mode
792
sFlow
Содержание S4048-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Страница 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Страница 477: ...Figure 68 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 477 ...
Страница 480: ...Figure 70 Inspecting a LAG Port on BRAVO Using the show interface Command 480 Link Aggregation Control Protocol LACP ...
Страница 481: ...Figure 71 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 481 ...
Страница 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Страница 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Страница 524: ...Figure 89 Configuring PIM in Multiple Routing Domains 524 Multicast Source Discovery Protocol MSDP ...
Страница 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Страница 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Страница 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Страница 633: ...Policy based Routing PBR 633 ...
Страница 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Страница 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...