SMI::enterprises.6027.3.30.1.1.1 SNMPv2-SMI::enterprises.6027.3.30.1.1 = STRING:
"NOT_REACHABLE: Syslog server
10.11.226.121 (port: 9140) is not reachable" SNMPv2-SMI::enterprises.6027.3.6.1.1.2.0 =
INTEGER: 2
Following is the sample audit log message that other syslog servers that are reachable receive:
Oct 21 00:46:13: dv-fedgov-s4810-6: %EVL-6-NOT_REACHABLE:Syslog server 10.11.226.121 (port:
9140) is not reachable
Following example shows the SNMP trap that is sent when connectivity to the syslog server is resumed:
DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (10230) 0:01:42.30 SNMPv2-
MIB::snmpTrapOID.0 = OID: SNMPv2-
SMI::enterprises.6027.3.30.1.1.2 SNMPv2-SMI::enterprises.6027.3.30.1.1 = STRING:
"REACHABLE: Syslog server
10.11.226.121 (port: 9140) is reachable"SNMPv2-SMI::enterprises.6027.3.6.1.1.2.0 = INTEGER:
2
Following is the sample audit log message that other syslog servers that are reachable receive:
Oct 21 05:26:04: dv-fedgov-s4810-6: %EVL-6-REACHABLE:Syslog server 10.11.226.121 (port:
9140) is reachable
Copy Configuration Files Using SNMP
To do the following, use SNMP from a remote client.
•
copy the running-config file to the startup-config file
•
copy configuration files from the Dell Networking system to a server
•
copy configuration files from a server to the Dell Networking system
You can perform all of these tasks using IPv4 or IPv6 addresses. The examples in this section use IPv4 addresses; however, you can
substitute IPv6 addresses for the IPv4 addresses in all of the examples.
The following table lists the relevant MIBs for these functions are.
Table 86. MIB Objects for Copying Configuration Files via SNMP
MIB Object
OID
Object Values
Description
copySrcFileType
.1.3.6.1.4.1.6027.3.5.1.1.1.1.2
1 = Dell Networking OS file
2 = running-config
3 = startup-config
Specifies the type of file to
copy from. The range is:
•
If copySrcFileType is
running-config or startup-
config, the default
copySrcFileLocation is
flash.
•
If copySrcFileType is a
binary file, you must also
specify
copySrcFileLocation and
copySrcFileName.
copySrcFileLocation
.1.3.6.1.4.1.6027.3.5.1.1.1.1.3
1 = flash
2 = slot0
3 = tftp
4 = ftp
5 = scp
6 = usbflash
Specifies the location of source
file.
•
If copySrcFileLocation is
FTP or SCP, you must
specify copyServerAddress,
copyUserName, and
copyUserPassword.
Simple Network Management Protocol (SNMP)
805
Содержание S4048-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Страница 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Страница 477: ...Figure 68 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 477 ...
Страница 480: ...Figure 70 Inspecting a LAG Port on BRAVO Using the show interface Command 480 Link Aggregation Control Protocol LACP ...
Страница 481: ...Figure 71 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 481 ...
Страница 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Страница 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Страница 524: ...Figure 89 Configuring PIM in Multiple Routing Domains 524 Multicast Source Discovery Protocol MSDP ...
Страница 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Страница 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Страница 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Страница 633: ...Policy based Routing PBR 633 ...
Страница 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Страница 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...