The Manage Partitions page is displayed.
2.
In the Read-Only column:
– Select the checkbox for the partition(s) and click Apply to change to read-only.
– Clear the checkbox for the partition(s) and click Apply to change to read-write.
The partitions are changed to read-only or read-write, based on the selections.
NOTE: If the partition is of type CD, the state is read-only. You cannot change the state to read-write. If the
partition is attached, the check box is grayed-out.
Modifying a Partition Using RACADM
To view the available partitions and their properties on the card:
1.
Open a telnet, SSH, or Serial console to the system and log in.
2.
Use any one of the following:
– Using
config
command to change the read-write state of the partition:
* To change a read-only partition to read-write:
racadm config –g cfgvflashpartition –i 1 –o
cfgvflashPartitionAccessType 1
* To change a read-write partition to read-only:
racadm config –g cfgvflashpartition –i 1 –o
cfgvflashPartitionAccessType 0
– Using
set
command to change the read-write state of the partition:
* To change a read-only partition to read-write:
racadm set iDRAC.vflashpartition.<index>.AccessType 1
* To change a read-write partition to read-only:
racadm set iDRAC.vflashpartition.<index>.AccessType 0
– Using
set
command to specify the Emulation type:
racadm set iDRAC.vflashpartition.<index>.EmulationType <HDD, Floppy, or
CD-DVD>
Attaching or Detaching Partitions
When you attach one or more partitions, they are visible to the operating system and BIOS as USB mass storage
devices. When you attach multiple partitions, based on the assigned index, they are listed in an ascending order in the
operating system and the BIOS boot order menu.
If you detach a partition, it is not visible in the operating system and the BIOS boot order menu.
When you attach or detach a partition, the USB bus in the managed system is reset. This affects applications that are
using vFlash and disconnects the iDRAC7 Virtual Media sessions.
Before attaching or detaching a partition, make sure that:
•
The vFlash functionality is enabled.
•
An initialize operation is not already being performed on the card.
•
You have Access Virtual Media privileges.
204
Содержание iDRAC7
Страница 1: ...Integrated Dell Remote Access Controller 7 iDRAC7 Version 1 50 50 User s Guide ...
Страница 14: ...14 ...
Страница 36: ...36 ...
Страница 66: ...66 ...
Страница 92: ...92 ...
Страница 144: ...144 ...
Страница 165: ...165 ...
Страница 166: ...166 ...
Страница 172: ...172 ...
Страница 184: ...184 ...
Страница 196: ...196 ...
Страница 208: ...208 ...
Страница 216: ...216 ...
Страница 220: ...220 ...
Страница 234: ...234 ...
Страница 248: ...248 ...