Scheduling Automatic Firmware Update Using Web Interface
To schedule automatic firmware update using Web Interface:
NOTE: Do not create the next scheduled occurrence of an automatic update job if a job is already Scheduled. It
overwrites the current scheduled job.
1.
In the iDRAC7 Web interface, go to Overview
→
iDRAC Settings
→
Update and Rollback .
The Firmware Update page is displayed.
2.
Click the Automatic Update tab.
3.
Select the Enable Automatic Update option.
4.
Select any of the following options to specify if a system reboot is required after the updates are staged:
– Schedule Updates — Stage the firmware updates but do not reboot the server.
– Schedule Updates and reboot Server — Enables server reboot after the firmware updates are staged.
5.
Select any of the following to specify the location of the firmware images:
– Network — Use the catalog file from a network share (CIFS or NFS). Enter the network share location details.
– FTP — Use the catalog file from the FTP site. Enter the FTP site details.
6.
Based on the selection in step 5, enter the network settings or the FTP settings.
For information about the fields, see the
iDRAC7 Online Help
.
7.
In the Update Window Schedule section, specify the start time for the firmware update and the frequency of the
updates (daily, weekly, or monthly).
For information about the fields, see the
iDRAC7 Online Help
.
8.
Click Schedule Update.
The next scheduled job is created in the job queue. Five minutes after the first instance of the recurring job starts,
the job for the next time period is created.
Scheduling Automatic Firmware Update Using RACADM
To schedule automatic firmware update, use the following commands:
•
To enable automatic firmware update:
racadm set lifecycleController.lcattributes.AutoUpdate.Enable 1
•
To view the status of automatic firmware update:
racadm get lifecycleController.lcattributes.AutoUpdate
•
To schedule the start time and frequency of the firmware update:
racadm AutoUpdateScheduler create -u username –p password –l <location> [-f
catalogfilename -pu <proxyuser> -pp<proxypassword> -po <proxy port> -pt
<proxytype>] -time < hh:mm> [-dom < 1 – 28,L,’*’> -wom <1-4,L,’*’> -dow <sun-
sat,’*’>] -rp <1-366> -a <applyserverReboot (1-enabled | 0-disabled)>
For example,
– To automatically update firmware using a CIFS share:
racadm AutoUpdateScheduler create -u admin -p pwd -l //1.2.3.4/CIFS-share
–f cat.xml -time 14:30 -wom 1 -dow sun -rp 5 -a 1
– To automatically update firmware using FTP:
racadm AutoUpdateScheduler create -u admin -p pwd -l ftp.mytest.com -pu
puser –pp puser –po 8080 –pt http –f cat.xml -time 14:30 -wom 1 -dow sun -
rp 5 -a 1
57
Содержание iDRAC7
Страница 1: ...Integrated Dell Remote Access Controller 7 iDRAC7 Version 1 50 50 User s Guide ...
Страница 14: ...14 ...
Страница 36: ...36 ...
Страница 66: ...66 ...
Страница 92: ...92 ...
Страница 144: ...144 ...
Страница 165: ...165 ...
Страница 166: ...166 ...
Страница 172: ...172 ...
Страница 184: ...184 ...
Страница 196: ...196 ...
Страница 208: ...208 ...
Страница 216: ...216 ...
Страница 220: ...220 ...
Страница 234: ...234 ...
Страница 248: ...248 ...