Recovering and Troubleshooting the Managed System
319
Critical
System Board OS Watchdog:
Watchdog sensor for System
Board, power cycle was asserted
iDRAC6 watchdog detected
that the system has crashed
(timer expired because no
response was received from
Host) and the action is set to
power cycle
Critical
System Board SEL: Event Log
sensor for System Board, log full
was asserted
The SEL device detects that
only one entry can be added to
the SEL before it is full
Warning
ECC Corr Err: Memory sensor,
correctable ECC
( <DIMM Location> ) was
asserted
Correctable ECC errors
reached a critical rate
Critical
ECC Uncorr Err: Memory sensor,
uncorrectable ECC
( <DIMM Location> ) was
asserted
An uncorrectable ECC error
was detected
Critical
I/O Channel Chk: Critical Event
sensor, I/O channel check NMI
was asserted
A critical interrupt is generated
in the I/O Channel
Critical
PCI Parity Err: Critical Event
sensor, PCI PERR was asserted
Parity error was detected on the
PCI bus
Critical
PCI System Err: Critical Event
sensor, PCI SERR
( <Slot number or PCI Device
ID>) was asserted
PCI error detected by device
Critical
SBE Log Disabled: Event Log
sensor, correctable memory error
logging disabled was asserted
Single bit error logging is
disabled when too many SBE
get logged
Critical
Logging Disabled: Event Log
sensor, all event logging disabled
was asserted
All error logging is disabled
Non-Recoverable CPU Protocol Err:
Processor sensor, transition to
non-recoverable was asserted
The processor protocol entered
a non-recoverable state
Table 20-8.
Server Status Screen
(continued)
Severity
Message
Cause
Содержание IDRAC6
Страница 1: ...Integrated Dell Remote Access Controller 6 iDRAC6 Enterprise for Blade Servers Version 2 1 User Guide ...
Страница 38: ...38 iDRAC6 Enterprise Overview ...
Страница 84: ...84 Configuring the Managed Server ...
Страница 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Страница 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Страница 166: ...166 Configuring Smart Card Authentication ...
Страница 222: ...222 Using GUI Console Redirection ...
Страница 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Страница 270: ...270 Using the RACADM Command Line Interface ...
Страница 308: ...308 Using iDRAC6 Configuration Utility ...
Страница 334: ...334 Recovering and Troubleshooting the Managed System ...
Страница 382: ...382 RACADM Subcommand Overview ...
Страница 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Страница 462: ...462 Glossary ...
Страница 472: ...472 Index ...