Using the RACADM Command Line Interface
259
racadm config -g cfgRacTuning -o
cfgRacTuneIpRangeMask 255.255.255.252
The last byte of the range mask is set to 252, the decimal equivalent of
11111100b.
IP Filtering Guidelines
Use the following guidelines when enabling IP filtering:
•
Ensure that
cfgRacTuneIpRangeMask
is configured in the form of a
netmask, where all most significant bits are 1’s (which defines the subnet
in the mask) with a transition to all 0’s in the low-order bits.
•
Use the desired range’s base address as the value of
cfgRacTuneIpRangeAddr
. The 32-bit binary value of this address should
have zeros in all the low-order bits where there are zeros in the mask.
Configuring IP Blocking
IP blocking dynamically determines when excessive login failures occur from
a particular IP address and blocks (or prevents) the address from logging in to
iDRAC6 for a preselected time span.
The IP blocking features include:
•
The number of allowed login failures (
cfgRacTuneIpBlkFailcount
)
•
The time frame in seconds during which these failures must occur
(
cfgRacTuneIpBlkFailWindow
)
•
The amount of time in seconds that the blocked IP address is prevented
from establishing a session after the allowed number of failures is exceeded
(
cfgRacTuneIpBlkPenaltyTime
)
As login failures accumulate from a specific IP address, they are registered by
an internal counter. When the user logs in successfully, the failure history is
cleared and the internal counter is reset.
NOTE:
When login attempts are refused from the client IP address, some SSH clients
may display the following message:
ssh exchange identification:
Connection closed by remote host
.
See "iDRAC6 Enterprise Property Database Group and Object Definitions"
for a complete list of
cfgRacTune
properties.
Содержание IDRAC6
Страница 1: ...Integrated Dell Remote Access Controller 6 iDRAC6 Enterprise for Blade Servers Version 2 1 User Guide ...
Страница 38: ...38 iDRAC6 Enterprise Overview ...
Страница 84: ...84 Configuring the Managed Server ...
Страница 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Страница 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Страница 166: ...166 Configuring Smart Card Authentication ...
Страница 222: ...222 Using GUI Console Redirection ...
Страница 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Страница 270: ...270 Using the RACADM Command Line Interface ...
Страница 308: ...308 Using iDRAC6 Configuration Utility ...
Страница 334: ...334 Recovering and Troubleshooting the Managed System ...
Страница 382: ...382 RACADM Subcommand Overview ...
Страница 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Страница 462: ...462 Glossary ...
Страница 472: ...472 Index ...