Recovering and Troubleshooting the Managed System
323
Critical
Mem Overtemp: Memory sensor,
correctable ECC <DIMM
Location> was asserted
Memory module overheating
Critical
Mem Fatal SB CRC: Memory
sensor, uncorrectable ECC
was asserted
South bridge memory failed
Critical
Mem Fatal NB CRC: Memory
sensor, uncorrectable ECC
was asserted
North bridge memory failed
Critical
WatchDog Timer: Watchdog
sensor, reboot was asserted
Watch dog timer caused
system to reboot
Critical
WatchDog Timer: Watchdog
sensor, timer expired was asserted
Watch dog timer expired but
no action taken
Warning
Link Tuning: Version Change
sensor, successful software or
F/W change was deasserted
Failed to update link tuning
setting for proper NIC operation
Warning
Link Tuning: Version Change
sensor, successful hardware
change <device slot number>
was deasserted
Failed to update link tuning
setting for proper NIC operation
Critical
LinkT/FlexAddr: Link Tuning
sensor, failed to program virtual
MAC address (Bus # Device #
Function #) was asserted
FlexAddress could not be
programmed for this device
Critical
LinkT/FlexAddr: Link Tuning
sensor, device option ROM failed
to support link tuning or flex
address (Mezz <location>)
was asserted
Option ROM does not support
FlexAddress or linking tuning
Critical
LinkT/FlexAddr: Link Tuning
sensor, failed to get link tuning or
flex address data from
BMC/iDRAC6 was asserted
Failed to obtain linking tuning
or FlexAddress information
from BMC/iDRAC6
Table 20-8.
Server Status Screen
(continued)
Severity
Message
Cause
Содержание IDRAC6
Страница 1: ...Integrated Dell Remote Access Controller 6 iDRAC6 Enterprise for Blade Servers Version 2 1 User Guide ...
Страница 38: ...38 iDRAC6 Enterprise Overview ...
Страница 84: ...84 Configuring the Managed Server ...
Страница 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Страница 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Страница 166: ...166 Configuring Smart Card Authentication ...
Страница 222: ...222 Using GUI Console Redirection ...
Страница 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Страница 270: ...270 Using the RACADM Command Line Interface ...
Страница 308: ...308 Using iDRAC6 Configuration Utility ...
Страница 334: ...334 Recovering and Troubleshooting the Managed System ...
Страница 382: ...382 RACADM Subcommand Overview ...
Страница 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Страница 462: ...462 Glossary ...
Страница 472: ...472 Index ...