Power Monitoring and Power Management
181
•
Reading
: The current power consumption in AC Amps
Power Tracking Statistics and Peak Statistics
•
Statistic:
–
Cumulative System Power
displays the current cumulative energy
consumption (in kWh) for the server. The value represents the total
energy used by the system. You can reset this value to 0 by clicking
Reset
at the end of the table row.
–
System Peak Power
specifies the system peak value in AC Watts.
System Peak Amperage
specifies the system peak amperage. The peak
value is the highest value recorded between the
Measurement Start
Time
and now. The peak time was the point in time when that peak
value occurred. Click
Reset
at the end of the table row to set it back to
the current instantaneous value (which, if the server is running, will
not be 0). Clicking reset will also reset the measurement start time to
the current time.
•
Measurement Start Time
displays the date and time recorded when the
system energy consumption value was last cleared and the new
measurement cycle began. For
Cumulative System Power
,
System Peak
Amperage
, and
System Peak Power
statistics, the peak values when reset,
will immediately reflect the current instantaneous value.
•
Measurement Current Time
for
Cumulative System Power
displays the
current date and time when the system energy consumption was
calculated for display. For
System Peak Amperage
and
System Peak Power
,
the
Peak Time
fields display the time when these peaks occurred.
•
Reading
: The value of the appropriate statistic—
Cumulative System Power
,
System Peak Power
, and
System Peak Amperage
since the counter was started.
NOTE:
Power Tracking Statistics are maintained across system resets and so reflect
all activity in the interval between the stated Start and Current times. The power
values displayed in the Power Consumption table are cumulative averages over the
respective time interval (last minute, hour, day and week). Since the Start to Finish
time intervals here may differ from those of the Power Tracking Statistics ones, peak
power values (Max Peak Watts versus Max Power Consumption) may differ.
Содержание IDRAC6
Страница 1: ...Integrated Dell Remote Access Controller 6 iDRAC6 Enterprise for Blade Servers Version 2 1 User Guide ...
Страница 38: ...38 iDRAC6 Enterprise Overview ...
Страница 84: ...84 Configuring the Managed Server ...
Страница 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Страница 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Страница 166: ...166 Configuring Smart Card Authentication ...
Страница 222: ...222 Using GUI Console Redirection ...
Страница 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Страница 270: ...270 Using the RACADM Command Line Interface ...
Страница 308: ...308 Using iDRAC6 Configuration Utility ...
Страница 334: ...334 Recovering and Troubleshooting the Managed System ...
Страница 382: ...382 RACADM Subcommand Overview ...
Страница 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Страница 462: ...462 Glossary ...
Страница 472: ...472 Index ...