Configuring and Using Serial Over LAN
193
NOTE:
If a SOL session is not closed successfully in the utility, more SOL sessions
may not be available. The way to resolve this situation is to terminate the command
line console in the Web GUI under
System
→
Remote Access
→
iDRAC6
→
Network/Security
→
Sessions
.
Using SOL over PuTTY
To start SOL from PuTTY on a Windows management station, follow
these steps:
NOTE:
If required, you can change the default SSH/Telnet timeout at
System
→
Remote Access
→
iDRAC6
→
Network/Security
→
Services
.
1
Connect to iDRAC6 with the following command at the command
prompt:
putty.exe [-ssh | -telnet] <
login name
>@<
iDRAC-ip-
address
> <
port number
>
NOTE:
The port number is optional. It is required only when the port number is
reassigned.
2
Enter the following command at the command prompt to start SOL:
connect
NOTE:
This connects you to the managed server's serial port. Once a SOL
session is established successfully, iDRAC6 command line console is no
longer available to you. Follow the escape sequence properly to reach
iDRAC6 command line console. Quit the SOL session using the command
sequence detailed in "Disconnecting SOL session in iDRAC6 Command Line
Console," and start a new one.
Using SOL over Telnet with Linux
To start SOL from Telnet on a Linux management station, follow these steps:
NOTE:
If required, you can change the default Telnet timeout at
System
→
Remote
Access
→
iDRAC6
→
Network/Security
→
Services
.
1
Start a shell.
2
Connect to iDRAC6 with the following command:
telnet <
iDRAC6-ip-address
>
NOTE:
If you have changed the port number for the Telnet service from the
default (port 23), add the port number to the end of the Telnet command.
Содержание IDRAC6
Страница 1: ...Integrated Dell Remote Access Controller 6 iDRAC6 Enterprise for Blade Servers Version 2 1 User Guide ...
Страница 38: ...38 iDRAC6 Enterprise Overview ...
Страница 84: ...84 Configuring the Managed Server ...
Страница 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Страница 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Страница 166: ...166 Configuring Smart Card Authentication ...
Страница 222: ...222 Using GUI Console Redirection ...
Страница 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Страница 270: ...270 Using the RACADM Command Line Interface ...
Страница 308: ...308 Using iDRAC6 Configuration Utility ...
Страница 334: ...334 Recovering and Troubleshooting the Managed System ...
Страница 382: ...382 RACADM Subcommand Overview ...
Страница 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Страница 462: ...462 Glossary ...
Страница 472: ...472 Index ...