Alert Message
Description/Meaning or Action
Fan <
number
> is missing.
Attach or replace the designated missing cooling fan.
Abnormal network errors detected on Network Interface
Controller <
number
>.
The Network Interface Controller errors could be caused
by network congestion or by packet errors.
•
Check your network. If that does not resolve the
problem, then replace the NIC.
•
If the NIC is embedded, the DR Series system
appliance requires service.
Network Interface Controller is missing.
•
Remove and reinsert the NIC.
•
If this does not resolve the problem, replace the NIC.
Network Interface Controller <
name
> is disconnected.
Connect it to a network and/or check your network
switches or routers for any network connectivity issues.
Network Interface Controller <
name
> is disabled.
Enable the port on the designated NIC.
Network Interface Controller <
name
> driver is bad.
Upgrade the DR Series system appliance (in the Software
Upgrade page, and click Start Upgrade).
CPU <
name
> failed.
Replace the designated failed processor.
CPU <
name
> is missing.
Reinsert or replace the designated missing processor.
DIMM <
name
> failed.
Replace the designated failed DIMM (Dual In-line Memory
Module) device.
DIMM <
name
> is missing.
•
Reinsert or replace the designated DIMM device.
•
The memory capacity of the storage appliance is
below the minimum required for correct operation.
•
The storage appliance requires service.
Temperature probe <
name
> failed.
The storage appliance requires service.
Voltage probe <
name
> failed.
The storage appliance requires service.
Temperature probes have recorded temperatures in the
failed range.
•
Check the Events page in the DR Series system for
specific temperature events and the location of the
temperature probes.
•
Check the data center air conditioning, ventilation, and
internal system cooling fans for any problems.
•
Ensure there is proper air flow through the storage
appliance, and as needed, clean the cooling vents.
Voltage probes have recorded readings in the failed
range.
•
Check the Events page in the DR Series system for
specific voltage events and the location of the voltage
probes.
•
Check the power supplies. If there are no issues with
the power supplies, have a service technician check
the DR Series system appliance to see if it requires any
servicing.
Storage Controller <
number
> failed.
Replace the RAID controller in the DR Series system.
164
Содержание DR series
Страница 1: ...Dell DR Series System Administrator Guide ...
Страница 10: ...10 ...
Страница 34: ...34 ...
Страница 138: ...138 ...
Страница 160: ...160 ...