System Event Message
Description/Meaning or Action
Filesystem server crashed multiple times. System is
now entering Maintenance mode.
Contact Dell Support for assistance or intervention.
Insufficient disk space. Filesystem switched to read-
only mode.
Informational message. No user intervention is required. If
issue persists, contact Dell Support for assistance or
intervention.
Unable to detect filesystem type on the Data Volume.
Contact Dell Support for assistance or intervention.
Unable to detect filesystem type on the Namespace
Volume.
Contact Dell Support for assistance or intervention.
Filesystem scan discovered inconsistencies.
Please check report and take the recommended action.
Contact Dell Support for assistance or intervention.
NVRAM does not match data volume.
If this is a newly replaced NVRAM device, use the CLI
maintenance --hardware --reinit_nvram command. For more
information, see the
Dell DR Series System Command Line
Reference Guide
.
Storage usage is approaching the DR Series system
capacity.
Informational message. No user intervention is required. If
issue persists, contact Dell Support for assistance or
intervention.
Replication resync cannot proceed because the
Namespace depth has reached its maximum.
Informational message. No user intervention is required. If
issue persists, contact Dell Support for assistance or
intervention.
Filesystem has reached the maximum allowable file(s)
and directories limit. New file and directory creation
will be denied until sufficient space exists.
Please clean up the filesystem. If issue persists, contact Dell
Support for assistance or intervention.
Filesystem is reaching the maximum allowable file(s)
and directories limit. New file and directory creation
will be denied after the limit has been reached.
Please clean up the filesystem. If issue persists, contact Dell
Support for assistance or intervention.
Replication has encountered an unexpected error.
Contact Dell Support for assistance or intervention.
DataCheck has detected a potential corruption.
Run data consistency checks at the first available opportunity.
If this issue persists, contact Dell Support for assistance or
intervention.
Temperature warning detected on NVRAM PCI
controller.
Please check the data center air conditioning, rack
ventilation, and internal cooling fans for any issues. Ensure
that there is proper air flow through the system appliance,
and clean the system cooling vents as needed. If issue
persists, contact Dell Support for assistance or intervention.
Filesystem Name Space partition has reached its
maximum allowable limit.
Please delete any old, unused file(s) or disable replication(s).
If issue persists, contact Dell Support for assistance or
intervention.
Filesystem Name Space partition is reaching its
maximum allowable limit.
New replication resynch(s) will be stopped. If issue persists,
contact Dell Support for assistance or intervention.