background image

38.

DSD31 / DSD33

Features

* DSD31 / DSD33

* True galvanic isolation design ensures that such serious AC mains problems as noise, lightning

   effects, leakage current do not reach your systems.

* Protection from the accidental disconnection of the neutral wire ensures the safety of the UPS

  and the stability of the power supply.

* Protection from incorrect operation ensures that violating the operation procedures will not

  lead to UPS or connected equipment damage.

* The use of up-to-date DSP, IGBT and switching components ensures the high reliability and

   efficiency of the UPS.

* Multi-CPU design increases the system reliability.

* Plug-and-play design and easy access to boards ensures the fastest and easiest UPS 

  maintenance.

* Individual inverter for each phase ensures stable work under completely unbalanced load.

* Intelligent charger with temperature compensation feature ensures the longest possible battery

  life. The adjustable level of charging current allows the UPS to work with large battery banks for

  long backup time.

* Intelligent battery test logics eliminate the possibility of power supply interruption during battery

  test in case of batteries being bad. Provides the detection of battery electrolyte leakage and

  improper battery grounding.

* Intelligent fan speed control increases the fan life expectancy and reduces the audible noise.

* Advanced heat abstraction design by physical separation of the power and control circuitry

  ensures the smooth operation of the UPS under most harsh conditions.

* Cold start function makes it possible to start the UPS even when AC mains are not providing the

  power.

* 12-pulse rectifier ensures reduced harmonics for UPS with capacities of 80KVA and higher.

* Input harmonic filter reduces the Total Harmonic Distortion (T.H.D.) of the UPS.

* Parallel operation makes it possible to upgrade the UPS to a larger capacity.

Line Interactive 

UPS Series

On Line UPS

Series

A

VR Series

Inverter Series

Surge Series 

Standby UPS

Series

Networking

Series

Green Power

 Series 

Содержание DS-D33

Страница 1: ...tery life The adjustable level of charging current allows the UPS to work with large battery banks for long backup time Intelligent battery test logics eliminate the possibility of power supply interruption during battery test in case of batteries being bad Provides the detection of battery electrolyte leakage and improper battery grounding Intelligent fan speed control increases the fan life expe...

Страница 2: ...e Certificate CE EN50091 1 2 FCC CLASSA Short Circuit Protection Lightning Protection EMC Filter Galvanic Isolation LED LCD Buzzer Start On Battery 3 Phase Input 3 Phase Output 10 15 20 30 40 50 60 80 100 120 160 200 240 300 320 400 92 92 93 93 93 5 93 5 94 94 5 94 5 95 95 95 95 95 95 95 1 3 1 3 1 3 1 3 1 9 2 6 3 3 5 4 6 5 4 6 5 8 7 13 17 4 17 4 18 1600 800 380 400 415VAC 20 20 is available upon r...

Страница 3: ...E EN50091 1 2 FCC CLASSA Short Circuit Protection Lightning Protection EMC Filter Galvanic Isolation LED LCD Buzzer Start On Battery 1600 800 380 400 415VAC 20 20 is available upon request 50 60Hz 5Hz 0 100 20sec 98 5 z 50 Hz Sinewave 0 8 1 0 60Hz 3H 60Hz 0 1 0 5 2 Continuous 15 minutes 10 minutes 1 minute 4 TRAL 173 277VAC LINE TO NEU 5 55 Hz 55 65 Hz 99 5 0 ms 30 sec 1 sec YES 0 40 32 96 0 90 No...

Страница 4: ...al cabinets of UPS and battery are aligned together It can accommodate Lead Acid maintenance free battery 26Ah 12V 29 pcs 1 set or 58 pcs 2 sets Dimension H xW x Dmm 1600 x 550 x 800 Weight 26Ah 12V x 29 pcs x 1 set is about 360kgs 26Ah 12V x 29 pcs x 2 sets is about 620kgs DSD 10K 60K DSD 80K 160K DSD 200K 400K Line Interactive UPS Series On Line UPS Series AVR Series Inverter Series Surge Series...

Отзывы: