FIELD
J
OB
3-40
3.6.2 SOFTWARE CONFIGURATION
MAIN MENU
SUB MENU
Explanation of functions
Remarks
LOGGER DATA
TRIP DATA
Data recorded in the logger is read
No information
DOWNLOAD
USDA DATA
from the controller onto the personal
appears on the
4-PULP SENSORS DATA
computer (disk or hard disk).
screen at this time.
PTI DATA
(This operation is called the
ALL DATA AFTER
download).
TRIP-START
CONTAINER I.D. SET CONTAINER I.D.
The logger header (set point temperature, Disk
/HEADER
/HEADER
cargo name, destination and other
/
Controller
-From DISK
information) is changed.
¡
Data previously saved on disk is
transmitted to the controller.
CHANGE CONTAINER I.D.
The container No. (container ID)
Input from
-From Keyboard
set in the controller is changed.
keyboard
CHANGE CONTAINER
The logger header is changed.
Input from
HEADER
keyboard
-From Keyboard
CHANGE CALENDAR
The internal clock on the
Conversion from
controller is changed.
personal computer
¡
The controller clock is based on GMT
built-in clock
(Greenwich Mean Time)
MAINTENANCE
DISPLAY CURRENT
Controller sensor values, operation of
Record on disk
& REPAIR
OPERATING DATA
internal relay and opening rates of SMV
is enabled.
and EV are displayed on the screen.
DISPLAY CURRENT
Detected alarms are displayed.
ALARM
DISPLAY ALARM LOG
Information of alarm recorded
Record on disk
in the logger is displayed.
is enabled.
DISPLAY
Fluctuation of control temperature
TEMPERATURE CHART
which has been recorded in the logger
is displayed in a graphic chart.
REPLACE BATTERY
The back-up battery replacement
Setting can be also
day is set and displayed.
made on the
control panel.
USDA CALIBRATION
The pulp sensor (USDA sensor) to The ice bath
(3-PULP
USDA SENSORS
be used for low temperature
is used.
SENSORS)
transportation is calibrated.
COLD
DISPLAY TEMPERATURE
Fluctuation of the pulp sensor
-TREATMENT
CHART
(USDA sensor) temperature which
has been recorded in the logger is
displayed in a graphic chart. Summary
report of trip data is indicated.
4-PULP
CALIBRATION
The pulp sensor (USDA sensor)
The ice bath
SENSORS
4-PULP SENSORS
to be used for low temperature
is used.
transportation is calibrated.
COLD
DISPLAY
Fluctuation of the pulp sensor
-TREATMENT
TEMPERATURE CHART
(USDA sensor) temperature which
has been recorded in the logger is
displayed in a graphic chart. Summary
report of trip data is indicated.