3-8
Indication of detailed data and alarm
●
Return air temperature (RS)
●
Pulp temperature (USDA #1, #2, #3)
●
Cargo temperature (CTS)
●
Data recorder supply air temperature (DSS)
●
Data recorder return air temperature (DRS)
※
5. Sensor indication mode
P 3-16
Each sensor value can be indicated.
●
Discharge gas temperature (DCHS)
●
Suction gas temperature (SGS)
●
Modulating valve opening
●
Electronic expansion valve opening
●
Supply air temperature (SS)
●
High pressure (HPT)
●
Low pressure (LPT)
●
Total current (CT1)
●
Compressor current (CT2)
●
Voltage (PT1)
●
Ambient temperature (AMBS)
●
Evaporator inlet temperature (EIS)
※
6. Temperature record scroll function
P 3-19
Temperature record of the control sensor
can be indicated in the order (scroll
indication) from the latest data.
●
Chilled mode: Supply air temperature
●
Frozen mode: Return air temperature
(up to 7 days)
※
7. Alarm record scroll function
P 3-22
Alarm record can be indicated in order
(scroll indication) from the latest data.
●
Alarm indication
(up to 7 days)
●
Evaporator outlet temperature (EOS)
[optional]
●
Fresh air quantity (FA)