3-2
No.
Function division
Function
DECOS
3
d
5
Self-diagnosis and
• Open-phase running
✓
automatic back-up
• Over current running
✓
• CPU and peripheral device (electronic controller)
✓
6
Manual inspection
• Compressor running hour indication
✓
• Evaporator fan individual operation (high speed)
✓
• Evaporator fan individual operation (low speed)
✓
• Condenser fan individual operation
✓
• Indication of elapsed time since trip start/time resetting
✓
• Evaporator fan run-hour indication
✓
• Condenser fan run-hour indication
✓
• Controller software version indication
✓
• [PC] --- Pulp temperature sensor/cargo temperature sensor calibration
Optional
• [PC] --- Header information set of data logger
✓
• [PC] --- All sensor data indication
✓
• [PC] --- Controller built-in relay output display/MV output
✓
(opening rate) indication/EV output (opening rate) indication
7
Automatic PTI
• Automatic PTI (SHORT) = Operation check of components
✓
• Automatic PTI (FULL)
✓
8
Data logging
• Compressor total running hour
✓
• Evaporator fan motor total running hour
✓
• Condenser fan motor total running hour
✓
• Trip data
✓
• Pulp temperature data
Optional
• Cargo temperature data
Optional
• Fresh air quantity data
Optional
• Alarm logging data
✓
• Automatic PTI data
✓
• Event data
✓
9
Data retrieving
• [PC] --- Alarm data
✓
(Data output)
• [PC] --- Trip data
✓
• [PC] --- Automatic PTI data
✓
• [PC] --- Pulp temperature data
Optional
• [PC] --- Cargo temperature data
Optional
• [PC] --- Event data
✓
10
Communication
• Remote monitoring
Optional
• Remote control
Optional
11
Power back-up
※
Even while the power is off, the following works are possible.
• Setting, Temperature setting
✓
Humidity setting
Optional
Defrosting interval setting
✓
[PC] --- Container ID data setting
✓
• Saving the logger data record
✓
• Data retrieving (down loading)
✓
12
Chartless
• Alarm indication function (H code)
✓
• Operation history indication function (D code)
✓
• Pull-down time indication function (P code)
✓
• Temperature logging data indication on LCD in simple graphic chart
✓
13
G-SET mode
※
To be used when power supply capacity is small.
• Energy saving operation
✓
14
Data scroll
• Temperature log scroll indication function
✓
• Alarm log indication function
✓
15
Data input
※
The following works are possible using the indication panel
• Container ID (No.) entering
✓
• Controller time setting
✓
16
Automatic
• Refelgerant is collected into the receiver and condensor coil.
✓
Pump down
https://daikin-p.ru