1
4
3
2
(Outlet joint)
(Inlet joint)
1-2
1.3 BASIC OPERATION OF
REFRIGERATION UNIT
Operate the unit by the following
procedure.
1.3.1 Operation preparation
(1) Make sure that the compressor discharge
and suction side stop valves
q
,
w
are
opened.
(Refer 1.2 Basic name of components.)
(2) Connect the cooling water piping to joints.
(When the water cooled operation is
required.)
Cooling water piping connection (Air and water
cooled combination unit)
For water-cooled operation, connect the water
piping to feed water.
·
Connection method
1. Connect the inlet joint
e
.
2. Connect the outlet joint
r
.
·
Disconnection method
1. Disconnect the outlet joint
r
.
2. Disconnect the inlet joint
e
.
Connect the cooling water joint in the following
method.
Connection method: Insert a joint on the ship side in
the piping joint on the unit side and push it in until
you feel a click.
When connecting or disconnecting the joint, be
careful not to be subject to cooling water splashes.
Piping connection method on cooling water
outlet side
Disconnection method: Pull the joint on the ship side
toward you with Part A of the joint on the female side
pushed and held as shown by the arrow in figure
above.
[Note] While in water-cooled operation, do
not attempt to touch the condenser fan by
hand. (The condenser fan turns ON or
OFF to cool the control box.)