3-21
●
Example of TEMPERATURE RECORD SCROLL INDICATION MODE
※
It is assumed that the control temperature is the supply air temperature (SS) and the logging
interval is 1 hour, and the current date and time are June 27, 2002, 14:00.
COMP. DEFROST IN RANGE DE-HUMID.
-----
-----
-----
-----
-----
2 7
3.
1
SUPPLY
RETURN
ALARM
R.H.
0. 1
0 0
-----
-----
-----
-----
-----
0. C
2
SUPPLY
RETURN
ALARM
R.H.
0. 1
R S
the key for 3 seconds.
To restart, press and hold
-----
-----
-----
-----
-----
6. C
3
SUPPLY
RETURN
ALARM
R.H.
R S
One second later
One
second
later
One
second
later
Press the
or
Key
-----
-----
-----
-----
-----
SUPPLY
RETURN
ALARM
R.H.
5. 0
5. 0
2.
2 7
1
0 0
-----
-----
-----
-----
-----
SUPPLY
RETURN
ALARM
R.H.
2 0
3.
1
0 0
-----
-----
-----
-----
-----
SUPPLY
RETURN
ALARM
R.H.
5. 0
2 7
2.
1
0 0
2 7
2.
1
0 0
-----
-----
-----
-----
-----
SUPPLY
RETURN
ALARM
R.H.
The date/time, control temperature and the inside
temperature on the other side are indicated in turn.
Press the
or Non key operation
for 10 seconds.
or
Key
COMP. DEFROST IN RANGE DE-HUMID.
COMP. DEFROST IN RANGE DE-HUMID.
COMP. DEFROST IN RANGE DE-HUMID.
COMP. DEFROST IN RANGE DE-HUMID.
COMP. DEFROST IN RANGE DE-HUMID.
COMP. DEFROST IN RANGE DE-HUMID.
S
5. 0
2 7
2.
1
0 0
An example. p.m. 1:00 June 27, 2002
(To be displayed on LCD)
SS= – 0.1 ˚C (indicated on LED)
SUPPLY LED lights on.
ALARM LED lights on (when alarms exist).
An example.
Date of p.m. 1:00 June 27, 2002
RS= 0. 2 ˚C (displayed on LED)
SS= – 0.1 ˚C (displayed on LED)
SUPPLY LED lights on.
ALARM LED lights on
(when alarms exist).
Stop on the data of
p.m. 12:00 June 27, 2002
Restart the scroll indication on the point
where the process was stooped on the
data of p.m. 12:00 June 27, 2002
After completion of indication of
the oldest data (Final indication)
Scroll indication
Date of p.m. 12:00 June
27, 2002 (To be displayed on LCD)
SS= 5.0 ˚C (displayed on LED)
DEFROST LED lights on.
(during defrosting)
Date of p.m. 12:00 June
27, 2002
RS= 6.3 ˚C (indicated on LED)
DEFROST LED lights on.
(during defrosting)
※
To go back the current indication mode,
press the key.
※
If key operation is not performed within
5 minutes, the current indication mode
screen is resumed.
※
To return to the operation setting mode,
press the key.
u
y
t
r
e
w
q
Note: " " on the leftmost of the LED shows that the indication is of the temperature record scroll indication
mode.
https://daikin-p.ru
Содержание LXE10E-1
Страница 161: ...7 9 https daikin p ru ...
Страница 162: ...7 14 Schematic wiring diagram LXE10E 1 7 10 https daikin p ru ...
Страница 163: ...7 15 Stereoscopic wiring diagram LXE10E 1 7 11 https daikin p ru ...