3.3 Remote Controller <BRC1C62>
65
Remote Controllers
3.3
Remote Controller <BRC1C62>
3.3.1 Appearance and Functions
Note: For connection unit series
∗
If indoor units from the Connection unit series are connected within a single refrigerant system to indoor units from any
other series, cooling/heating switchover will not be possible using the remote contoroller of the Connection unit series
indoor units, However, if the remote controller of an indoor unit from the other series is set as a master remote
controller, cooling/heating switchover will be possible.
∗
If all indoor units are from the Connection unit series, an outdoor unit Cool/Heat selector will be needed to enable
cooling/heating switchover.
∗
In case of Heat Recovery System
Cooling/Heating changeover is possible when connecting with BS unit.
Control functions by remote controllers
Note: 1. 2-remote controller control: By connecting two remote controllers to one indoor unit, control may be made
freely from two places.
*2 When using 2 remote controllers, combined use with group remote control adapter is impossible.
2. Group control: A maximum of 16 indoor units may be controlled simultaneously by one remote controller.
3. Remote control: Remote control wiring may be extended to a maximum of 500 m and therefore the indoor unit
may be controlled from 500 m away. (Separate operation wireless remote controller type may be operated
from 200 m away.)
4. Combined control: Combined simultaneous control of the HRV unit with indoor units may be made.
Large liquid crystal screen displays complete operating status.
Digital display lets you set temperature in 1°C units.
Lets you individually program by timer the respective times for operation start and
stop within a maximum of 72 hours.
Equipped with a thermostat sensor in the remote controller that makes possible
more comfortable room temperature control.
Monitors room temperature and preset temperature by microcomputer, and can
select cool/heat operation mode automatically. (VRV System Heat Recovery
Series only)
Enables you to select cool / heat / fan operation mode with the indoor remote
controller of your choice without using the cool / heat selector. (VRV System
Inverter series, Heat Recovery series, Plus series)
Constantly monitors malfunctions in the system for 40 items, and is equipped
with a “self-diagnosis function” that lets you know by message immediately when
a malfunction occurs.
Lets you carry out various field settings by remote controller.
Ventilation mode change over and ventilation air flow switch for HRV.
2-remote
controller
control
Group
control
Remote
control
Combined
control
Remarks
Wired remote controllers
{
{
{
{
—
Wireless remote
controllers
Light receiver
incorporated
type
∆
(*1)
{
✕
∆
(*2)
*1.Possible if wired (main), wireless
(sub)
*2.Since there is no ventilation mode,
independent HRV unit operation is
impossible. Only simultaneous
ON/OFF with indoor unit is
possible.
Separate
light receiver
type
∆
(*1)
{
✕
∆
(*2)
Simplified remote controller
{
{
{
{
—
Содержание D-BACS
Страница 1: ...ED 72 721 Preliminary Daikin Buildings Air conditioning Control System D BACS DESIGN GUIDE ...
Страница 17: ...xvi 1 5 Open Network Glossary Introduction ...
Страница 41: ...24 Outline of D BACS System ...
Страница 74: ...57 Remote Controllers HRV Wired remote controller BRC301B61 VAM ...
Страница 88: ...3 6 Wired Remote Controller with Weekly Schedule Timer BRC1D61 71 Remote Controllers 3P107422 3D ...
Страница 102: ...5 2 Wireless Remote Controller BRC4C 7C 7E 85 Remote Controllers 5 2 Wireless Remote Controller BRC4C 7C 7E ...
Страница 103: ...86 5 3 Simplified Remote Controller BRC2C51 BRC2A51 Remote Controllers 5 3 Simplified Remote Controller BRC2C51 BRC2A51 ...
Страница 107: ...90 5 4 HRV BRC301B61 Remote Controllers ...
Страница 142: ...1 2 System Configuration 125 Control Devices 1 2 System Configuration System Outline ...
Страница 181: ...164 3 8 Error Diagnosing Function Control Devices ...
Страница 215: ...198 3 8 Wiring Example intelligent Manager ...
Страница 235: ...218 Interface for Use in BACnet ...
Страница 249: ...232 7 1 Node Objects Interface for use in LONWORKS 7 Object Details 7 1 Node Objects 7 2 DIII NET Common Objects ...
Страница 253: ...236 Interface for use in LONWORKS 10 Reference Materials Error Code Conversion Table ...
Страница 268: ...251 Interface for use in LONWORKS 13 Workflow ...
Страница 285: ...268 1 6 Notes Power Proportional Distribution P P D ...
Страница 319: ...302 1 5 Dio Unit DEC102A51 Adaptor 1 5 2 Part Names and Functions 1 Appearance Dio Unit DEC102A51 ...
Страница 329: ...312 1 6 Di Unit DEC101A51 Adaptor 1 6 2 Part Names and Functions 1 Appearance Di Unit DEC101A51 ...