Open Network Glossary
Term
Explanation
Ai Unit
Connecting adapter that communicates information from environmental sensors (temperature, pressure,
humidity and voltage/electric current) to measurement unit.
ANSI
American National Standards Institute
Architecture
Refers to the overall design concept of the computer from hardware to software.
It is a systematic layout detailing the connection between the communications network and the devices in an
open network.
ASHRAE
American Society of Heating, Refrigeration and Air-conditioning Engineers, Inc.
BACnet
Building Automation Control Network
BAS
Building Automation System
Users: Building management engineers
Main functions: Facility device status monitoring
Alarm monitoring
Operation management (scheduling)
Automatic control of facilities
Bind
Refers to one of the activities included in a test run. Specifically, the logical address is appropriated and
allocated.
Binding
Refers to the logical connecting between the network variables that the user wishes to communicate.
It is a setting that enables communication of nvo from one device/machine and nvi from another. This is a job
usually handled by an NI.
BMS
Building Management System
Refers to a system for building management (management of electricity charges, equipment and the like).
BASs are configured within BMSs.
Users: Building management engineers
Main functions: Facility equipment ledger management
Repair history management
Maintenance schedule management
Billing data
Well known BMS manufacturers in Japan include NEC, YBS, YJ, Fujitsu, Panasonic and Oki.
Broadcast
Refers to the simultaneous transmission of a message to all the devices connected in a system.
Messages involved in the communication between devices connected within a network are simultaneously
sent to all the devices within the network.
Centralized remote
controllers
Devices for collectively programming and managing operation of multiple air conditioners, installed in facility
from one or many locations.
Closed Network
Refers to a system configured by only one manufacturer that does not allow access by other manufacturers.
DIII-NET is one such example.
Commission
The work conducted when the central monitoring panel is connected to a gateway.
Specifically, the data within the gateway is sent to the central monitoring panel for data confirmation.
Refers to installation of settings in the node after the communication content is set via binding.
Communication Traffic
Volume
Refers to the traffic volume determined according to the number of nodes and network variables and the
frequency of communication between these two.
Configuration Property
Refers to parameters related to the behavior of the LON nodes. Configuration properties are set for the
respective nodes by an NI when the network is being installed. They are assigned to the nodes' nonvolatile
memory. Unlike network variables, configuration properties represent semi-fixed variable values.
CRC
Central Remote Controller
A device that allows remote controllers of up to 64 indoor units, groups or zones (total of 128 indoor units).
The single device provides centralized control to each connected indoor units for functions such as individual/
zone/simultaneous operation start/stop, room temperature control, etc. The device offers the same control
as individual remote controllers.
Содержание D-BACS
Страница 1: ...ED 72 721 Preliminary Daikin Buildings Air conditioning Control System D BACS DESIGN GUIDE ...
Страница 17: ...xvi 1 5 Open Network Glossary Introduction ...
Страница 41: ...24 Outline of D BACS System ...
Страница 74: ...57 Remote Controllers HRV Wired remote controller BRC301B61 VAM ...
Страница 88: ...3 6 Wired Remote Controller with Weekly Schedule Timer BRC1D61 71 Remote Controllers 3P107422 3D ...
Страница 102: ...5 2 Wireless Remote Controller BRC4C 7C 7E 85 Remote Controllers 5 2 Wireless Remote Controller BRC4C 7C 7E ...
Страница 103: ...86 5 3 Simplified Remote Controller BRC2C51 BRC2A51 Remote Controllers 5 3 Simplified Remote Controller BRC2C51 BRC2A51 ...
Страница 107: ...90 5 4 HRV BRC301B61 Remote Controllers ...
Страница 142: ...1 2 System Configuration 125 Control Devices 1 2 System Configuration System Outline ...
Страница 181: ...164 3 8 Error Diagnosing Function Control Devices ...
Страница 215: ...198 3 8 Wiring Example intelligent Manager ...
Страница 235: ...218 Interface for Use in BACnet ...
Страница 249: ...232 7 1 Node Objects Interface for use in LONWORKS 7 Object Details 7 1 Node Objects 7 2 DIII NET Common Objects ...
Страница 253: ...236 Interface for use in LONWORKS 10 Reference Materials Error Code Conversion Table ...
Страница 268: ...251 Interface for use in LONWORKS 13 Workflow ...
Страница 285: ...268 1 6 Notes Power Proportional Distribution P P D ...
Страница 319: ...302 1 5 Dio Unit DEC102A51 Adaptor 1 5 2 Part Names and Functions 1 Appearance Dio Unit DEC102A51 ...
Страница 329: ...312 1 6 Di Unit DEC101A51 Adaptor 1 6 2 Part Names and Functions 1 Appearance Di Unit DEC101A51 ...