176
1.2 Specification
intelligent Manager
1.2
Specification
1.2.1 intelligent Manager III Series and its Components
1.2.2 intelligent Manager III Optional Functions
1.2.3 Specification
1.2.4 intelligent Manager III Optional Adapters
Products name *1
Max number indoor units
Max number outdoor units
PC,UPS,etc.
Hardware model name
IM-256
256
40
DAM602B51x1
IM-128
128
20
DAM602B52
IM-512
512
80
DAM602B51x2
IM-768
768
120
DAM602B51x3
IM-1024
1024
160
DAM602B51x4
Local Procurement
Products name is recognised as an order number.
*1
Power Proportional Distribution
ECONO
Web access
DAM002A51
DAM003A51
DAM004A51
*
To use optional functions with intelligent Manager, one option
license must be purchased for each intelligent Manager system.
Performance
Network
Operation
Software
SVGA
Capacity
Voltage
Control signals
Relay I/ 0 module
Pulse transmitter
CPU:Pentium 800MHz,Memory:256MB,HDD:4G
100Base/T Ethernet
Keyboard/Mouse,Sound and Speaker
800x600,1024x768,1280x1024
A4 Page Printer
Multi Port HUB(4 or more parts)
200~250 W/20min
As required
Power failure signal (from UPS)
UPS shut down signal (to UPS)
AP9610
CRT
Printer
Network Equipment
PC
Windows XP(Professional SP2 or later)
Windows 2000(Professional SP4 or later)
Item
Requirement Specification
Requirement Specification
UPS
e.g. APC
SU700,
1000 series
WHM
(kWh meter)
for PPD
Item
· 1 pulse to 1kW or 10kW, width must be in
between 40-400m/sec.
· Output relay must be electronic type.
· No voltage output.
Data are filed into nonvolatile memory
2 (DAM602B52) / 4(DAM602B51)
20
2
2 (PC, modem)
1 (Memory card)
AC100~240V±10%,50/60Hz,Max 20W
-10~+50˚C
0~98%(condensation is not acceptable)
260(W)x281(H)x58.5(D)mm,4kg
iPU
Processing
Unit
DAM602B51
DAM602B52
Backup for power failure
D Port
Di/Pi Port
Do Port
RS232C Port
PCMCIA slot
Power supply
Ambient temperature
Ambient humidity
Dimension,mass
8pairs based on a pair of
On/Off input and abnormality input
4pairs based on a pair of
On/Off input and abnormality input
In case of normally output,
4 units are controllable.
In case of instantaneous output,
2 units are controllable.
1external temperature sensor
(mesurement of O/D temp : -10 to +50 )
and 1 multi-purpose sensor
Input
Output
Installation method
Operating
Condition
surrounding temperature
humidity
Power supply
Rated power consumption
Applied standard
Mass(Weight)
Dimension
Item
Di unit (DEC101A51)
Dio unit (DEC102A51)
D -Ai unit (DAM101A51)
10 to 85%
AC200V-240V,50/60Hz
15W
Safety standard : IEC730,EMC standard : CISPR22-A(EMI),CISPR(EMS)
indoor installation
-10 to +40
2.5kg
198(H) 335(W) 70(D)mm
Outdoors, with drip proof case
-15 to +50
1.5kg
211(H) 357(W) 75(D)mm
Содержание D-BACS
Страница 1: ...ED 72 721 Preliminary Daikin Buildings Air conditioning Control System D BACS DESIGN GUIDE ...
Страница 17: ...xvi 1 5 Open Network Glossary Introduction ...
Страница 41: ...24 Outline of D BACS System ...
Страница 74: ...57 Remote Controllers HRV Wired remote controller BRC301B61 VAM ...
Страница 88: ...3 6 Wired Remote Controller with Weekly Schedule Timer BRC1D61 71 Remote Controllers 3P107422 3D ...
Страница 102: ...5 2 Wireless Remote Controller BRC4C 7C 7E 85 Remote Controllers 5 2 Wireless Remote Controller BRC4C 7C 7E ...
Страница 103: ...86 5 3 Simplified Remote Controller BRC2C51 BRC2A51 Remote Controllers 5 3 Simplified Remote Controller BRC2C51 BRC2A51 ...
Страница 107: ...90 5 4 HRV BRC301B61 Remote Controllers ...
Страница 142: ...1 2 System Configuration 125 Control Devices 1 2 System Configuration System Outline ...
Страница 181: ...164 3 8 Error Diagnosing Function Control Devices ...
Страница 215: ...198 3 8 Wiring Example intelligent Manager ...
Страница 235: ...218 Interface for Use in BACnet ...
Страница 249: ...232 7 1 Node Objects Interface for use in LONWORKS 7 Object Details 7 1 Node Objects 7 2 DIII NET Common Objects ...
Страница 253: ...236 Interface for use in LONWORKS 10 Reference Materials Error Code Conversion Table ...
Страница 268: ...251 Interface for use in LONWORKS 13 Workflow ...
Страница 285: ...268 1 6 Notes Power Proportional Distribution P P D ...
Страница 319: ...302 1 5 Dio Unit DEC102A51 Adaptor 1 5 2 Part Names and Functions 1 Appearance Dio Unit DEC102A51 ...
Страница 329: ...312 1 6 Di Unit DEC101A51 Adaptor 1 6 2 Part Names and Functions 1 Appearance Di Unit DEC101A51 ...