Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 4.4.26
Engine start
3/3
►
Continuing
Abort starting procedure if :
-
No ignition 10 seconds after having positioned THROTTLE to
LO-IDLE,
-
lights on (max ITT < 870°C for more than 20 seconds,
< 1000°C for more than 5 seconds)
,
-
Ng < 30 % after 30 seconds of starter use
,
-
Ng < 50 % after 60 seconds of starter use
,
13 -
THROTTLE
CUT OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 -
IGNITION switch
OFF or AUTO
. . . . . . . . . . . . . . . . . . . .
When ITT < 850°C :
15 -
STARTER switch
ABORT
. . . . . . . . . . . . . . . . . . .
End of procedure
■
ITT
When
-
Ng > 50 % and,
-
1 minute max :
▲
CAUTION
▲
If the starter does not go off automatically, disengage it using the
ABORT position of the STARTER switch.
▲
16 -
Starter
Check OFF automatically
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 -
STARTER
Check OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 -
Engine parameters
Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check 54 %
≤
Ng
≤
58 %, oil pressure and ITT in green sector
End of procedure.