Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 1
Page 3.3.10
during takeoff
ITT HI
1 -
Continue takeoff normally.
When takeoff procedure is completed :
If AT is engaged :
2 -
AT
Disconnect
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 -
THROTTLE
Reduce
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To get ITT < 820°C
●
NOTE
●
Above 400 ft AGL, autothrottle engine protection system will reduce power to
get ITT below 820
°
C. The resulting engine power is sufficient to maintain
minimum climb gradients.
●
End of procedure.