Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 2
Page 3.11.7
STALL NO HEAT
Indicates that :
- stall warning vane heating has failed or
- PITOT L/R & STALL HTR switch is not ON while the engine is running.
Correct operation of the aural stall warning may be altered by severe or prolonged
icing.
1 -
Airspeed
Monitor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintain minimum airspeed according
to airplane configuration and icing conditions
►
Fly the airplane
◄
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS