Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.8.3
AUX BOOST PMP ON
Indicates the auxiliary booster pump is running.
►
Fly the airplane
◄
If AUX BP switch is in ON position :
Indication is normal.
End of procedure
■
If AUX BP switch is in AUTO position :
1 -
Reset AUX BP switch to
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -
Then, AUX BP switch
AUTO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If
AUX BOOST PMP ON
goes OFF :
3 -
Continue the flight normally.
End of procedure
■
If
AUX BOOST PMP ON
remains ON :
Mechanical booster pump has failed.
4 -
AUX BP switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
►
Land as soon as possible
◄
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS