Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 2
Page 3.9.5
and
2/3
MAIN GEN
LOW VOLTAGE
an
►
Continuing
9 -
GENERATOR selector
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If altitude > 10000 ft :
10 -
OXYGEN switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If VMC and non-icing conditions are possible :
11 -
ESS BUS TIE switch
EMER
. . . . . . . . . . . . . . . . . . . . . . . .
In this configuration, only both ESS BUS bars and
BATT BUS bar are directly supplied by the battery.
►
Land as soon as possible
◄
If use of other systems is required :
12 -
ESS BUS TIE switch
NORM
. . . . . . . . . . . . . . . . . .
End of procedure
■
If VMC and non-icing conditions are not possible :
13 -
Manually disconnect systems as follows :
Breakers :
-
PFD 2
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
ADC 2
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
TAS
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
DATA LINK
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
XPDR 2
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switches :
-
DE ICE SYSTEM mode
MAN
. . . . . . . . . . . . . . . . . . .
All deicing systems turn on
-
ICE LIGHT
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
INERT SEP
As required
. . . . . . . . . . . . . . . . . . . . . . .
-
AIRFRAME DE ICE
OFF
. . . . . . . . . . . . . . . . . . . . . .
-
PROP DE ICE
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Continue
►
PIM - DO NOT USE FOR FLIGHT OPERATIONS