Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.7.8
Emergency gear extension
2/3
►
Continuing
If :
- GEAR UNSAFE red warning light is OFF and
-
GEAR UNSAFE
is OFF and
- 3 green lights are ON :
8 -
Exit and / or remain outside icing conditions.
Continue flight at airspeed < 178 KIAS.
►
Land as soon as practical
◄
End of procedure
■
If :
- GEAR UNSAFE red warning light is ON and
-
GEAR UNSAFE
is ON and
- 0 to 3 green lights are ON :
9 -
LDG GEAR breaker
Push
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 -
CHECK DOWN push-button
Press
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If :
- hardening of the pump is marked and
- 3 green lights are ON or
- 3 green lights are ON and flickering while pressing the CHECK DOWN
push-button :
11 -
Land
End of procedure
■
Continue
►