Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.8.4
FUEL LOW L-R
Indicates a level drop in the corresponding tank.
1 -
Corresponding gage
Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -
Check the other tank has been automatically selected.
If other tank not automatically selected :
3 -
FUEL SEL switch
MAN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 -
Select tank manually
As required
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
►
Fly the airplane
◄
5 -
Minimum fuel
Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 -
Take decision.
If necessary :
►
Land as soon as practical
◄
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS