Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.9.3
LOW VOLTAGE
Normal functioning with GENERATOR selector on MAIN.
1 -
Voltmeter voltages
. Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If voltages are < 26 V :
2 -
Monitor a possible voltage drop or any indication of battery discharge.
►
Fly the airplane
◄
3 -
Keep the following systems connected :
-
Autopilot system
-
Deicing systems
-
STROBE and NAV lights
-
Cockpit emergency lights
-
VHF 1
-
NAV/GPS 1
-
BLEED
-
LDG LIGHTS on short final
This will allow to keep electrical consumption
below maximum standby capacity.
All other not necessary equipment can be disconnected.
4 -
GENERATOR selector
ST- BY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If necessary :
5 -
ST-BY GENERATOR RESET push-button
Press
. . . . . . . . . . . .
6 -
Maintain ST-BY loads below 100 A.
End of procedure.