Configuring sFlow
D-Link
Unified Wired and Wireless Access System
Oct. 2015
Page 155
D-Link UWS User Manual
• Use the
Submit
button to sent updated data to the switch and cause the changes to take effect on the
switch.
• Use the
Refresh
button to refresh the page with the most current data from the switch.
Table 67: sFlow Receiver Configuration
Field
Description
Receiver Index Selects the receiver for which data is to be displayed or configured. The allowed range is 1 to
8.
Receiver Owner
String
The entity making use of this sFlowRcvrTable entry. The empty string indicates that the entry
is currently unclaimed and the receiver configuration is reset to the default values. An entity
wishing to claim an sFlowRcvrTable entry must ensure that the entry is unclaimed before
trying to claim it. The entry is claimed by setting the owner string. The entry must be claimed
before any changes can be made to other sampler objects.
Receiver
Timeout
The time (in seconds) remaining before the sampler is released and stops sampling. A
management entity wanting to maintain control of the sampler is responsible for setting a
new value before the old one expires. Allowed range is (0 to 2147483647 secs). A value of
zero sets the selected receiver configuration to its default values.
No Timeout
Select the check box to set the timeout value to non-decrementing value of 2147483647
seconds for a receiver. As the receiver entry will be deleted in the configuration only after
timeout value is Zero, 'No Timeout' selected entry will be in the config until user explicitly
removes the entry.
Receiver
Maximum
Datagram Size
The maximum number of data bytes that can be sent in a single sample datagram. The
manager should set this value to avoid fragmentation of the sFlow datagrams. The default
value is 1400. The allowed range is 200 to 9116.)
Receiver
Address
The IP address of the sFlow collector. If set to 0.0.0.0 no sFlow datagrams will be sent.
Receiver Port
The destination port for sFlow datagrams. The allowed range is 1 to 65535). The default
value for port is 6343
Receiver
Datagram
Version
The version of sFlow datagrams that should be sent.