Appendix B: Fault codes
B-9
Fault codes
Document no.:
S-4-007.875/E
Prepared:
1995-03-17 Fia
Revision:
R4 2004-03-15 BM
©
2002, Consilium Marine AB
146 HIGH VOLTAGE (Abn. condition)
Cause
Remedy
Too high system voltage from
power unit.
Test the rectifier and measure the
voltage.
Too high voltage:
→
Exchange the
rectifier.
Normal voltage:
→
Exchange the
IOK-4 board.