5
4. Remove the Devices
There are two methods to remove learned-in
devices:
command removing
and
local
removing
.
4.1. Command Removing
Command Removing
The user can use Commands 80-82 to
remove learned-in devices from the system.
1.
Command 80
is used to remove
ALL
previously learnt-in devices.
2.
Command 81
is used to remove
Zone
1
device.
3.
Command 82
is used to remove
Zone
2
device.
Please refer to
5.3 Programming Your
SUPER 32-DT35A
for details.
The PC Programming Tool (Super Tool) also
supports
Command Removing
. Please refer
to
5.4. PC Programming Mode (Super Tool)
5.4.1.6 Device
for detailed instructions.
4.2. Local Removing
Under Local Learning Mode, the devices
learnt into Zone 1 and Zone 2 can be
removed by pressing and holding the Learn
Button for 6 seconds.
1. Press and hold the Learn Button of the
SUPER 32-DT35A. When pressed, the
SUPER 32-DT35A will emit one beep
sound initially, and then will emit a double
beep on the 6th second.
2. Release the Learn Button at the voice
prompt “Release the button, Ready to
learn sensor.” SUPER 32-DT35A is now in
learning mode and the white backlight will
start flashing quickly.
3. Under learning mode, press & hold the
Learn Button again for 6 seconds. (When
pressed, the SUPER 32-DT35A will emit
one beep sound initially, and then will emit
a long beep on the 6th second.)
4. Release the Learn Button after the long
beep. SUPER 32-DT35A will voice prompt
“Release the button, Ready to learn
sensor.” Both Pendants have been
removed.
5. Press the Learn button once to exit
Learning Mode. SUPER 32-DT35A will
return to idle mode. Voice Prompt: “We
are now in Normal Operation Mode.
”
6. If no action after 5 minutes, the SUPER
32-DT35A will automatically exit Local
Learning Mode and return to idle mode.
Voice Prompt: “We are now in Normal
Operation Mode.”
<NOTE>
After the SUPER 32-DT35A has been
powered on for over
1 hour
, devices in
Zone 1 and Zone 2 cannot be removed. If
Learn Button
is pressed for 6 seconds,
the SUPER 32-DT35A will emit a 5
countinouus beep to indicate remove
failure. To remove the devices, SUPER
32-DT35A must power down and power
back on again.