7.7. SUPER 32-DT35A Voice Prompts
The Control Panel plays voice prompts on important occasions to report its condition or remind you
to take a specific action. Information on voice prompts is provided in the chart below.
Voice Prompt
Condition
Release the Button
Played once after long pressing (6 seconds) the Learn Button on the
Control Panel to enter learning mode.
Ready to learn sensor
Played once after entering learning mode
Press Sensor Button
Played once if no action within 10 seconds after “Ready to learn sensor”
prompt. This prompt will repeat two times if no action.
Press the Button to exit
Played once i
f no action after second “Press Sensor Button” prompts.
This prompt will be repeated three times if no action continues.
{Sensor Type} Learned
Played in learning mode, when the button on the device or sensor is
pressed
Low Battery
Played when the sensor is learned in with low battery status.
We are now in normal operation mode
Played once when the Learn Button was pressed to exit learning mode.
Played once after five minutes of no action in learning mode. The Control
Panel as returned to idle mode.
Emergency Button
Played once when the sensor has been learnt into the Control Panel
Panic Button
Played once when the sensor has been learnt into the Control Panel
Smoke Detector
Played once when the sensor has been learnt into the Control Panel
Fall Sensor
Played once when the sensor has been learnt into the Control Panel
Carbon Monoxide Detector
Played once when the sensor has been learnt into the Control Panel
Pull Cord
Played once when the sensor has been learnt into the Control Panel
Power on
Played when the Panel is powered on
Calling the Care Center
Played once after pressing the Help Button on the Control Panel, Active
Button on Panic Button, WTR, Fall Sensor or DECT device.
Played once every 2-3 seconds during guard time.
Emergency call cancelled
Played twice when the reset button is pressed during guard time
A fall has been detected
Played once when a fall sensor is triggered.
Played once every 2-3 seconds during guard time.
Fall detection has restored, cancelling help
call
Played after the reception of a fall sensor’s cancel code
Fire Alarm
Played when fire has been detected.
Call has ended
Played when the Alarm Dial Call Reporting is successful.
Carbon Monoxide Alarm
Played when specific levels of carbon monoxide is detected by Carbon
Monoxide Detector
Power failure, check power cord
Played twice when a power failure takes place
Power restored
Played once when power is restored
Inactivity timer expiring, please reset
Played once every 5 minutes during Warning Period (default 30 minutes).
After Warning Period, the Control Panel will start reporting to Monitoring
Centre.
Inactivity timer reset
Played once when the inactivity timer has been reset
Phone line problem. Check your connection
Played twice when there is a telephone line problem
Phone line connection restored
Played once when a telephone line problem is fixed.
High Temperature Alarm
Played when high temperature has been detected.
Low Temperature Alarm
Played when low temperature has been detected.
Please take medication
Played when medication is not taken by patient.
Unit has been disabled
Played when alarm is activated, but system reporting is disabled.
Test Call being placed
Played when the test button is pressed.