4
3. Learn-in the Devices
There are three methods to learn in devices:
command learning,
local learning
, and
learn in using Device ID
. The system can
learn a total of 20 sensors.
3.1. Command Learning
Command Learning
:
1.
The user can use Commands
93 & 94
to learn devices into the system.
2.
Command 93
is designed to learn in
devices for silent reporting.
3.
Command 93 & 94
is designed to learn
in the following devices and sensors.
PIR Sensor ----- PIR
Smoke Detector ---- SD
Carbon Monoxide Detector----
CO
Carbon Dioxide Detector ----
CO2
Temperature Sensor ---- TS
Fixed Panic Button ---- PB
Wrist Transmitter ---- WTR
Pendant Transmitter ---- WTR
Water Sensor ---- WS
Fall Sensor ---- FS
Medication Dispenser
Please refer to
5.3 Programming Your
SUPER 32-DT35A
for details.
The PC Programming Tool (Super Tool) also
supports
Command Learning
. Please refer
to
5.4. PC Programming Mode (Super Tool)
5.4.1.6 Device
for detailed instructions.
3.2. Local Learning
Local Learning Mode
:
The user can also use the local learning
method to learn in all devices.
When the device is learnt in for the first
time, voice prompt will prompt the
device/sensor name and “learned.”
Within 3 minutes after exiting learning
mode, the control panel will emit 1 long
beep everytime it receives a test code
(from any device).
Learn in Devce under Local Learning Mode:
1. Press and hold the Learn Button of the
SUPER 32-DT35A. When pressed, the
SUPER 32-DT35A will emit one beep
sound initially, and then will emit a double
beep on the 6
th
second.
2. Release the Learn Button at the voice
prompt “Release the button, Ready to
learn sensor.” SUPER 32-DT35A is now in
learning mode and the white backlight will
start flashing quickly.
3. Press the (Learn) button on the device or
sensor. Voice Prompt: “(Name of Sensor)
learned.”
4. If no action withi
n 10 seconds after “Ready
to learn sensor” prompt, SUPER 32-
DT35A
will prompt “Press sensor button.”
This prompt will repeat two times if no
action.
5.
If no action after second “Press sensor
button” prompt, SUPER 32-DT35A will
prompt “Press button to exit.” This prompt
will be repeated three times if no action
continutes.
6. If no action after 5 minutes, the SUPER
32-DT35A will automatically exit Local
Learning Mode and return to idle mode.
Voice Prompt: “We are now in Normal
Operation Mode.”
3.3. Learn-In Device using
Device ID
If sensor device ID is given (please refer to
label sticking on the device or consult the
supplier), the users can learn the device into
the Control Panel using device ID.
The PC Programming Tool (Super Tool) also
supports
learn in using Device ID
. Please
refer to
5.4. PC Programming Mode (Super
Tool) 5.4.1.6 Device
for detailed instructions.